Lactate-Glo™ Assay

J5021_Lactate-Glo Assay-5ml_3
customize-this-small
View information on global supply logistics

Quick, Sensitive Lactate Assay for a Variety of Biological Samples

  • Perform in high-throughput workflows
  • Multiplex with other metabolite or viability assays
  • Linear lactate detection range up to 200µM

Presentación

Catalog number selected: J5021

$ 513.00
Your price:
Add to Cart
This product is discontinued
Solicitar una Muestra Add to Helix
This product is available under our Early Access program - Learn More
This product is available under our Catalog (FT) program - Learn More
Lactate-Glo™ Assay
5ml
$ 513.00
Your price: Acceder
Cambiar Configuración

Sensitive, Rapid Lactate Detection from a Variety of Samples

The Lactate-Glo™ Assay is a bioluminescent assay for rapid, selective and sensitive detection of L-lactate in biological samples. Lactate is produced by glycolysis, a major metabolic pathway responsible for glucose homeostasis and energy production. Once considered merely a byproduct of glycolysis, lactate is now considered an important regulatory molecule of intermediate metabolism involved in cancer development, diabetes and other diseases. This means lactate detection can be used to measure changes in glycolysis.

 

How the Lactate Assay Works

The Lactate-Glo™ Assay couples lactate oxidation and NADH production with a bioluminescent NADH detection system. Lactate dehydrogenase uses lactate and NAD+ to produce pyruvate and NADH. In the presence of NADH a pro-luciferin Reductase Substrate is converted by Reductase to luciferin, which is then used in a luciferase reaction to produce light. The Lactate-Glo™ Assay contains an L-lactate-selective lactate dehydrogenase to confer specificity for L-lactate, the major stereoisomer found in mammalian cells.

When Lactate Detection Reagent, which contains lactate dehydrogenase (LDH), NAD+, Reductase, Reductase Substrate and Luciferase, is added to a sample containing lactate at a 1:1 ratio, the enzyme-coupled reactions start and run simultaneously. The luminescent signal is proportional to the amount of lactate in the sample and increases until all lactate is consumed at which time a stable luminescent signal is achieved.

 

Meets Your Throughput and Workflow Requirements

The Lactate-Glo™ Assay is a versatile detection kit that is amenable to high-throughput formats and compatible with many sample types. To simplify your sample processing, the lactate detection assay uses processing methods that do not require sample centrifugation or spin columns. Simply dilute your samples, add inactivation and neutralization solutions if needed, and assay all samples directly in 96- or 384-well plates.

 

Luminescent Signal is Proportional to Lactate Present in Sample

13887ma-w: Luminescence from lactate assay proportional to metabolite.
Lactate titration curve. Serial dilutions of lactate were prepared as described in TM493, and lactate detected using the Lactate-Glo™ Assay.

Lactate Secretion by A549 Cells

13888ma-w: Luminescent lactate assay measured secretion for 72 hours.
A549 cells were plated at 5,000 (light blue bars) and 15,000 (dark blue bars) cells/well as described in TM493. Red line represents the luminescence of medium-only controls. Samples were taken from the medium at times indicated and the amount of lactate measured using the Lactate-Glo™ Assay. 

Advantages of Lactate-Glo™ Assay

Quickly Detect Lactate in a Variety of Sample Types: Measure in medium, cells, tissue and plasma. The lactate detection assay requires minimal preparation steps with no need for centrifugation and spin columns.

Conduct easy in-well processing for intracellular detection.

Detect Small Changes in Lactate Levels Across a Wide Range of Concentrations: Sensitive lactate assay with broad linearity better discriminates small changes in lactate compared to colorimetric and fluorometric lactate assays.

Gain More Information Per Sample: The lactate detection assay along with the other bioluminescent metabolite detection assays are amenable to measuring multiple metabolites from the same sample. Multiplex with cell viability assays for normalization.

Requires Only a Luminometer: The same plate reader that measures cell viability can be used to monitor glycolysis. No specialized instruments, plates or artificial medium are required.

Measure Multiple Metabolites from One Sample

Easily measure changes in cellular glycolysis and glutaminolysis by sampling medium over time. Direct measurement of four metabolites important to the energetic state of the cell—glucose, lactate, glutamate and glutamine—can be performed in parallel using the bioluminescent Glucose-Glo™, Lactate-Glo™, Glutamine/Glutamate-Glo™ and Glutamate-Glo™ Assays. No specialized instrument, plates or artificial medium is required. Sample processing compatible with all of the bioluminescent metabolite assays means the same sample can be used for detecting all four metabolites. This includes sample types such as culture medium, serum, plasma and tissue. The data below were produced by measuring metabolites using medium samples from the same cell cultures as described in Technical Manual TM494.

13836ma-w-a: Glucose consumption measured in metabolite multiplex assay.
13836ma-w-b: Lactate secretion measured in metabolite multiplex assay.
13836ma-w-c: Glutamine consumption measured in metabolite multiplex assay.
13836ma-w-d: Glutamate secretion measured in metabolite multiplex assay.

Especificaciones

You are viewing: J5021 Cambiar Configuración

Contenido

Item Part # Presentación Concentración

Reductase

G884A 1 × 55μl 6mg/ml

Reductase Substrate

G885A 1 × 55μl

Luciferin Detection Solution

J135A 1 × 5ml

NAD

J136A 1 × 30μl

Lactate

J137A 1 × 50μl

Lactate Dehydrogenase

J195A 1 × 1 each

Certificado de Análisis

Search by lot number

Use Restrictions

For Research Use Only. Not for Use in Diagnostic Procedures.

Condiciones de Almacenaje

AA

Patentes y Exclusiones

U.S. Pat. Nos. 9,273,343 and 9,951,372, European Pat. No. 2751089, Japanese Pat. No. 6067019 and other patents pending.

Especificaciones

You are viewing: J5022 Cambiar Configuración

Contenido

Item Part # Presentación Concentración

Reductase

G884B 1 × 275μl 6mg/ml

Reductase Substrate

G885B 1 × 275μl

Luciferin Detection Solution

J135B 1 × 50ml

NAD

J136B 1 × 275μl

Lactate

J137A 1 × 50μl

Lactate Dehydrogenase

J195A 1 × 1 each

Certificado de Análisis

Search by lot number

Use Restrictions

For Research Use Only. Not for Use in Diagnostic Procedures.

Condiciones de Almacenaje

AA

Patentes y Exclusiones

U.S. Pat. Nos. 9,273,343 and 9,951,372, European Pat. No. 2751089, Japanese Pat. No. 6067019 and other patents pending.

Encontremos el producto que se adapte a sus necesidades.

Hablar con un científico

Paraj

Paraj

US