Canine PD-1/PD-L1 Blockade Bioassay
Canine PD-1/PD-L1 Blockade Bioassay
Catalog No. | Product Name | Size | Price | Qty | |||
---|---|---|---|---|---|---|---|
CS348807 | Early Access Canine PD-1/PD-L1 Blockade Bioassay | View Specifications | 1 each | Consultar Precio | |||
CS348809 | Early Access Canine PD-1/PD-L1 Blockade Bioassay 5X | View Specifications | 1 each | Consultar Precio | |||
CS348803 | Early Access Canine PD-1/PD-L1 Blockade Bioassay, Propagation Model | View Specifications | 1 each | Consultar Precio | |||
CS348811 | Early Access PD-1/PD-L1 Bioassay, Cell Bank | View Specifications | 1 each | Consultar Precio |
Early Access = This product is available under our Early Access program - Learn More
Catalog (FT) = This product is available under our Catalog (FT) program - Learn More
Leading the Pack: Canine PD-1/PD-L1 Blockade Bioassay
Canine immune checkpoint therapeutics are a recent development in companion animal medicine, building on the success of immune-checkpoint inhibitor treatment in humans. Similar to their human counterpart, the canine immune system relies on checkpoint molecules on immune cells to control an immune response, but this mechanism has also been exploited by canine tumors to avoid detection. Emerging studies in veterinary oncology are focused on discovering and developing canine-targeted antibodies for immune checkpoints, such as CTLA-4 and PD-1/PD-L1.
There are several challenges to developing canine-specific antibodies for immune checkpoints, such as low-efficacy and low-throughput screening measures due to lack of standardized reagents and protocols, leading to labor-intensive assays with high levels of variability.
The Canine PD-1/PD-L1 Blockade Bioassay is a two-cell-line system, a target cell that expresses canine PD-L1 and an effector reporter cell that expresses canine PD-1. The assay is a biologically relevant MoA-based and robust system that can be used to measure the potency and stability of biologics designed to block canine PD-1/PD-L1 interaction. This bioassay reduces data variability and provides a convenient luminescent readout.
Demonstrate Canine PD-1/PD-L1 Blockade
Principle of Canine PD-1/PD-L1 Blockade Bioassay. The Canine PD-1/PD-L1 Blockade Bioassay consists of two genetically engineered cell lines, the CHO-K1 target cells and the PD-1 reporter effector cell. When co-cultured, the PD-1/PD-L1 interaction inhibits TCR-mediated luminescence. When the PD-1/PD-L1 interaction is disrupted, TCR activation induces luminescence that can be detected by addition of Bio-Glo™ Reagent and quantitation with a luminometer.
Assay Workflow: Standardized Reagents to Improve Your Results
- Thaw-and-use cell format provides significant time and labor savings over traditional methods while reducing variability.
- Kit includes all of the required reagents in standardized formats.
- Easily amenable to high-throughput workflows.
Assay Performance Data
Canine PD-1 Effector Cells were co-cultured with Canine PD-L1 aAPC/CHO-K1 Cells in the presence of a titration of Anti-Canine PD-L1 Blocking Antibody. After 6 hours, Bio-Glo™ Reagent was added and plates were read on a GloMax® Discover Luminometer.
Interested in additional animal health bioassays?
Contact us to learn about our bioassay development services.
Protocols
No protocols available
Specifications
Catalog Number:
Contenido
Item | Part # | Presentación |
---|---|---|
Canine PD-1 Effector Cells |
CS348804 | 1 × 0.5ml |
Canine PD-L1 aAPC/CHO-K1 Cells |
CS348805 | 1 × 0.5ml |
RPMI 1640 Medium |
G708A | 1 × 36ml |
Bio-Glo™ Luciferase Assay Buffer |
G719A | 1 × 10ml |
Bio-Glo™ Luciferase Assay Substrate |
G720A | 1 × 1 vial |
Fetal Bovine Serum |
J121A | 1 × 4ml |
Ham's F-12 Medium |
J123A | 1 × 25ml |
SDS
Search for SDSCertificado de Análisis
Promega Cell Line Limited Use Label License (LULL)
BY USE OF THIS MATERIAL, RECIPIENT AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE.
-
1. Usage and Transfer Restrictions:
- 1.1. Recipient may use this material for research use only, which includes but is not limited to drug discovery and development, quality assurance testing and product release assays. No transfer, resale or commercial use of this material is allowed without the written consent of Promega Corporation.
- 1.2. “Commercial use” means any and all uses of this material or derivatives by recipient for monetary or other consideration, including product manufacture, providing a service, information or data to unaffiliated third parties and resale of the material for any use.
-
2. Modification Restrictions:
- 2.1. Recipient shall have no right to modify, derivatize or otherwise create variations of the nucleotide sequence of any proprietary gene, including but not limited to luciferase, NanoBiT® technology (e.g., HiBiT), HaloTag® technology or genes stably transfected within the cells.
- 2.2. Recipient shall have no right to genetically engineer or otherwise modify the cell line.
-
3. Propagation and Storage:
- 3.1. The recipient may not propagate the cells, unless material is marked as Propagation Model, Cell Bank or Master Cell Bank; then recipient may propagate and store the cells for long-term use.
-
4. For all determinations of luminescence or other assay-related activity of this material and its derivatives, recipient must either:
- 4.1. Use the detection systems specified in the protocol or data report and purchased from Promega for all luminescence assays when using this material; or
- 4.2. Contact Promega to obtain a license for use of this material with reagents other than a Bio-Glo™ branded luciferase reagent, including but not limited to:
- 4.2.1 Bio-Glo™, Bio-Glo-NL™, Bio-Glo-NB™ TCK, Bio-Glo-NB™ VLP, Bio-Glo-NB™ Lytic
-
5. For uses of this material for energy transfer (such as bioluminescence resonance energy transfer), recipient must:
- 5.1. Use NanoBRET™-branded luminescent assay reagents (LARs; e.g., NanoBRET™ Nano-Glo® Substrate), Intracellular TE Nano-Glo® Substrate/Inhibitor or Intracellular TE Nano-Glo® Vivazine™/Inhibitor for all determinations of luminescent activity by this material and its derivatives; and
- 5.2. Use NanoBRET™-branded energy acceptors (e.g., NanoBRET™ tracers, NanoBRET™ dyes, BRET-optimized HaloTag® ligands) for all determinations of energy transfer activity by this material and its derivatives; or
- 5.3. Contact Promega to obtain a license for the use of the material and its derivatives for energy transfer assays to energy acceptors not manufactured by Promega. No license is needed if the energy transfer acceptor is a genetically encoded autofluorescent protein.
-
6. For uses of HaloTag® Technology in this material, recipient must either:
- 6.1. Use Promega HaloTag® ligands, which can be modified or linked to Promega or customer-supplied moieties; or
- 6.2. Contact Promega to obtain a license if Promega HaloTag® ligands are not to be used.
-
7. Disclaimer and Governing Law:
- 7.1. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE MATERIAL. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.
Contenido
Item | Part # | Presentación |
---|---|---|
Canine PD-1 Effector Cells |
CS348804 | 5 × 0.5ml |
Canine PD-L1 aAPC/CHO-K1 Cells |
CS348805 | 5 × 0.5ml |
RPMI 1640 Medium |
G708A | 5 × 36ml |
Bio-Glo™ Luciferase Assay Buffer |
G719A | 5 × 10ml |
Bio-Glo™ Luciferase Assay Substrate |
G720A | 5 × 1 vial |
Fetal Bovine Serum |
J121A | 5 × 4ml |
Ham's F-12 Medium |
J123A | 5 × 25ml |
SDS
Search for SDSCertificado de Análisis
Promega Cell Line Limited Use Label License (LULL)
BY USE OF THIS MATERIAL, RECIPIENT AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE.
-
1. Usage and Transfer Restrictions:
- 1.1. Recipient may use this material for research use only, which includes but is not limited to drug discovery and development, quality assurance testing and product release assays. No transfer, resale or commercial use of this material is allowed without the written consent of Promega Corporation.
- 1.2. “Commercial use” means any and all uses of this material or derivatives by recipient for monetary or other consideration, including product manufacture, providing a service, information or data to unaffiliated third parties and resale of the material for any use.
-
2. Modification Restrictions:
- 2.1. Recipient shall have no right to modify, derivatize or otherwise create variations of the nucleotide sequence of any proprietary gene, including but not limited to luciferase, NanoBiT® technology (e.g., HiBiT), HaloTag® technology or genes stably transfected within the cells.
- 2.2. Recipient shall have no right to genetically engineer or otherwise modify the cell line.
-
3. Propagation and Storage:
- 3.1. The recipient may not propagate the cells, unless material is marked as Propagation Model, Cell Bank or Master Cell Bank; then recipient may propagate and store the cells for long-term use.
-
4. For all determinations of luminescence or other assay-related activity of this material and its derivatives, recipient must either:
- 4.1. Use the detection systems specified in the protocol or data report and purchased from Promega for all luminescence assays when using this material; or
- 4.2. Contact Promega to obtain a license for use of this material with reagents other than a Bio-Glo™ branded luciferase reagent, including but not limited to:
- 4.2.1 Bio-Glo™, Bio-Glo-NL™, Bio-Glo-NB™ TCK, Bio-Glo-NB™ VLP, Bio-Glo-NB™ Lytic
-
5. For uses of this material for energy transfer (such as bioluminescence resonance energy transfer), recipient must:
- 5.1. Use NanoBRET™-branded luminescent assay reagents (LARs; e.g., NanoBRET™ Nano-Glo® Substrate), Intracellular TE Nano-Glo® Substrate/Inhibitor or Intracellular TE Nano-Glo® Vivazine™/Inhibitor for all determinations of luminescent activity by this material and its derivatives; and
- 5.2. Use NanoBRET™-branded energy acceptors (e.g., NanoBRET™ tracers, NanoBRET™ dyes, BRET-optimized HaloTag® ligands) for all determinations of energy transfer activity by this material and its derivatives; or
- 5.3. Contact Promega to obtain a license for the use of the material and its derivatives for energy transfer assays to energy acceptors not manufactured by Promega. No license is needed if the energy transfer acceptor is a genetically encoded autofluorescent protein.
-
6. For uses of HaloTag® Technology in this material, recipient must either:
- 6.1. Use Promega HaloTag® ligands, which can be modified or linked to Promega or customer-supplied moieties; or
- 6.2. Contact Promega to obtain a license if Promega HaloTag® ligands are not to be used.
-
7. Disclaimer and Governing Law:
- 7.1. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE MATERIAL. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.
Contenido
Item | Part # | Presentación |
---|---|---|
Canine PD-1 Effector Cells (CPM) |
CS348801 | 2 × 1ml |
Canine PD-L1 aAPC/CHO-K1 Cells (CPM) |
CS348802 | 2 × 1ml |
Promega Cell Line Limited Use Label License (LULL)
BY USE OF THIS MATERIAL, RECIPIENT AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE.
-
1. Usage and Transfer Restrictions:
- 1.1. Recipient may use this material for research use only, which includes but is not limited to drug discovery and development, quality assurance testing and product release assays. No transfer, resale or commercial use of this material is allowed without the written consent of Promega Corporation.
- 1.2. “Commercial use” means any and all uses of this material or derivatives by recipient for monetary or other consideration, including product manufacture, providing a service, information or data to unaffiliated third parties and resale of the material for any use.
-
2. Modification Restrictions:
- 2.1. Recipient shall have no right to modify, derivatize or otherwise create variations of the nucleotide sequence of any proprietary gene, including but not limited to luciferase, NanoBiT® technology (e.g., HiBiT), HaloTag® technology or genes stably transfected within the cells.
- 2.2. Recipient shall have no right to genetically engineer or otherwise modify the cell line.
-
3. Propagation and Storage:
- 3.1. The recipient may not propagate the cells, unless material is marked as Propagation Model, Cell Bank or Master Cell Bank; then recipient may propagate and store the cells for long-term use.
-
4. For all determinations of luminescence or other assay-related activity of this material and its derivatives, recipient must either:
- 4.1. Use the detection systems specified in the protocol or data report and purchased from Promega for all luminescence assays when using this material; or
- 4.2. Contact Promega to obtain a license for use of this material with reagents other than a Bio-Glo™ branded luciferase reagent, including but not limited to:
- 4.2.1 Bio-Glo™, Bio-Glo-NL™, Bio-Glo-NB™ TCK, Bio-Glo-NB™ VLP, Bio-Glo-NB™ Lytic
-
5. For uses of this material for energy transfer (such as bioluminescence resonance energy transfer), recipient must:
- 5.1. Use NanoBRET™-branded luminescent assay reagents (LARs; e.g., NanoBRET™ Nano-Glo® Substrate), Intracellular TE Nano-Glo® Substrate/Inhibitor or Intracellular TE Nano-Glo® Vivazine™/Inhibitor for all determinations of luminescent activity by this material and its derivatives; and
- 5.2. Use NanoBRET™-branded energy acceptors (e.g., NanoBRET™ tracers, NanoBRET™ dyes, BRET-optimized HaloTag® ligands) for all determinations of energy transfer activity by this material and its derivatives; or
- 5.3. Contact Promega to obtain a license for the use of the material and its derivatives for energy transfer assays to energy acceptors not manufactured by Promega. No license is needed if the energy transfer acceptor is a genetically encoded autofluorescent protein.
-
6. For uses of HaloTag® Technology in this material, recipient must either:
- 6.1. Use Promega HaloTag® ligands, which can be modified or linked to Promega or customer-supplied moieties; or
- 6.2. Contact Promega to obtain a license if Promega HaloTag® ligands are not to be used.
-
7. Disclaimer and Governing Law:
- 7.1. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE MATERIAL. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.
Promega Cell Line Limited Use Label License (LULL)
BY USE OF THIS MATERIAL, RECIPIENT AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE.
-
1. Usage and Transfer Restrictions:
- 1.1. Recipient may use this material for research use only, which includes but is not limited to drug discovery and development, quality assurance testing and product release assays. No transfer, resale or commercial use of this material is allowed without the written consent of Promega Corporation.
- 1.2. “Commercial use” means any and all uses of this material or derivatives by recipient for monetary or other consideration, including product manufacture, providing a service, information or data to unaffiliated third parties and resale of the material for any use.
-
2. Modification Restrictions:
- 2.1. Recipient shall have no right to modify, derivatize or otherwise create variations of the nucleotide sequence of any proprietary gene, including but not limited to luciferase, NanoBiT® technology (e.g., HiBiT), HaloTag® technology or genes stably transfected within the cells.
- 2.2. Recipient shall have no right to genetically engineer or otherwise modify the cell line.
-
3. Propagation and Storage:
- 3.1. The recipient may not propagate the cells, unless material is marked as Propagation Model, Cell Bank or Master Cell Bank; then recipient may propagate and store the cells for long-term use.
-
4. For all determinations of luminescence or other assay-related activity of this material and its derivatives, recipient must either:
- 4.1. Use the detection systems specified in the protocol or data report and purchased from Promega for all luminescence assays when using this material; or
- 4.2. Contact Promega to obtain a license for use of this material with reagents other than a Bio-Glo™ branded luciferase reagent, including but not limited to:
- 4.2.1 Bio-Glo™, Bio-Glo-NL™, Bio-Glo-NB™ TCK, Bio-Glo-NB™ VLP, Bio-Glo-NB™ Lytic
-
5. For uses of this material for energy transfer (such as bioluminescence resonance energy transfer), recipient must:
- 5.1. Use NanoBRET™-branded luminescent assay reagents (LARs; e.g., NanoBRET™ Nano-Glo® Substrate), Intracellular TE Nano-Glo® Substrate/Inhibitor or Intracellular TE Nano-Glo® Vivazine™/Inhibitor for all determinations of luminescent activity by this material and its derivatives; and
- 5.2. Use NanoBRET™-branded energy acceptors (e.g., NanoBRET™ tracers, NanoBRET™ dyes, BRET-optimized HaloTag® ligands) for all determinations of energy transfer activity by this material and its derivatives; or
- 5.3. Contact Promega to obtain a license for the use of the material and its derivatives for energy transfer assays to energy acceptors not manufactured by Promega. No license is needed if the energy transfer acceptor is a genetically encoded autofluorescent protein.
-
6. For uses of HaloTag® Technology in this material, recipient must either:
- 6.1. Use Promega HaloTag® ligands, which can be modified or linked to Promega or customer-supplied moieties; or
- 6.2. Contact Promega to obtain a license if Promega HaloTag® ligands are not to be used.
-
7. Disclaimer and Governing Law:
- 7.1. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE MATERIAL. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.
Resources
Featured Resource
Webinar: Precision in Veterinary Nucleic Acid Purification: Optimizing Complex Samples
Join us for the first installment of our Veterinary and Animal Health webinar series, where our veterinary scientist Dr. Patrícia Eri Ishii, DVM, Ph.D., will demonstrate the power of advanced sample purification techniques. The webinar will explore how the Promega Maxwell Instrument simplifies the nucleic acid extraction and purification process across various complex samples in animal health diagnostics. Attendees will gain insights into using Promega chemistries to support diverse sample types and enhance the accuracy of diagnostic and research workflows.
Related Products
Productos Similares
Canine FcγRIII ADCC Bioassay
Characterize the Fc effector activity of antibodies mediating ADCC through the canine FcγRIII receptor.
CS3631A05, CS3631A07, CS3631A02
PD-1+TIGIT Combination Bioassay
Characterize biologics designed to block PD-1/PD-L1 and TIGIT/CD155, alone or in combination.
J2211, J2215, J2102, J2051, J1921
Mouse FcγRIV ADCC Bioassay
Characterize the Fc effector activity of antibodies that bind and activate the mouse mFcγRIV receptor.
M1201, M1211, M1215, M1212
SIRPα/CD47 Blockade Bioassay
Measure the potency and stability of biologics that bind and block SIRPα/CD47 interactions.
JA6011, JA6015, JA6012, GA6000, GA6040, K1251
Usado con frecuencia junto con
GloMax® Discover System
Lector de microplacas de alto rendimiento para la detección de luminiscencia, fluorescencia y absorbancia.
GM3000
PD-1/PD-L1 Blockade Bioassay
Measure the ability of biologics to block immune checkpoint signals
J1250, J1255, J1252, J1191, J1195, J1201
Thaw-and-Use Primary Effector Cells
Consistent and robust method for target cell killing.
CS3055C02, CS3055C03, CS3055B03, CS3055B06, CS3055A15, CS3055A18
ADCC Reporter Bioassay, V Variant
Measure potency and stability of antibodies mediating ADCC through the high-affinity human FcγRIIIa-V receptor.
G7015, G7014, G7010, G7016, G7013, G7018, G7102, GA1130