Lumit® IL-17A (Human) Immunoassay
No-Wash Immunoassay for IL-17A Detection
- Fast add-and-read protocol performed directly on cells
- Luminescent detection with any microplate luminometer
- Scalable to 96- or 384-well plates
Catalog Number:
Choose a product
Size
$ 597.00
Catalog Number: W1430
$ 3,887.00
Catalog Number: W1431
$ 2,234.00
Catalog Number: W1432
$ 135.00
Catalog Number: W143A-C
Log In to see your price
Quantify IL-17A Release Without Tedious Wash Steps
IL-17A, a pro-inflammatory cytokine, is a pivotal player in inflammation as it mediates the host’s defense against pathogens and is involved in the pathogenesis of various inflammatory and autoimmune diseases. Therapeutically targeting IL-17A shows a reduction in inflammation and improves clinical outcomes in autoimmune conditions.
The Lumit® IL-17A Immunoassay quantitatively measures released IL-17A in cell culture samples using a simple, no-wash protocol. Just add labeled antibodies to the sample, add detection reagent and read luminescent signal using a standard plate-reading luminometer. The entire protocol is completed in less than 70 minutes. The assay can be used directly on cells in culture or culture medium transferred to a separate assay plate.
How the Lumit® IL-17A Immunoassay Works
Primary antibodies to IL-17A were selected for their specific and sensitive detection and labeled with the LgBiT and SmBiT subunits of NanoBiT® Luciferase. In the presence of IL-17A, the subunits are brought together to form an active luciferase enzyme. Addition of optimized substrate generates a bright luminescent signal proportional to IL-17A levels. The assay is specific to IL-17A and does not detect B, D, E and F family members.
Simple One-Plate Protocol Requires No Wash Steps
Broad Linear Range of Lumit® IL-17A Detection
The picomolar to nanomolar linear detecton range of Lumit® IL-17A Immunoassay covers expected concentrations for most cell models.
Specification |
Lumit® IL-17A Immunoassay |
|
Dynamic Range |
18.2–25,000pg/ml |
|
Limit of Detection (LOD) |
2.2pg/ml (3 SD above background) |
|
Minimal Detectable Dose (MDD) |
1.3pg/ml (2 SD above background) |
|
Assay Time |
70 minutes |
|
Sample Type |
Cell culture supernatants |
SD=Standard Deviation
For a biotech that understands time is of significant value, the Lumit® Immunoassays are an essential way for us to gather reliable data fast so that we can reach conclusions and make decisions sooner.
Jonathan Chow, Principal Scientist, Corner Therapeutics
Featured Webinar
Optimizing the Lumit® IL-6 Immunoassay for High-Throughput Drug Screening
In this webinar, we share key considerations for scaling Lumit® Immunoassays from a single 96-well plate to many 364-well plates and offer tips for optimizing Lumit® Immunoassays for HTS applications. You will also hear Galapagos scientist Dr. Nick Verstraeten share how his team used the Lumit® IL-6 Immunoassay in a screening campaign for antiviral drugs.
Lumit® Detection of IL-17A Release from PBMCs
Peripheral Blood Mononuclear Cells (PBMC) were plated in 96-well plate format at 100,000 cells/well in RPMI 1640 + 10% heat-inactivated FBS. Cells were treated in quadruplicate for 48 hours with increasing concentrations of cell stimulation cocktail (a mixture of PMA and ionomycin). Following treatment, IL-17A release was quantitated using the Lumit® IL-17A Immunoassay.
Protocols
Specifications
Catalog Number:
What's in the box?
Item | Part # | Size |
---|---|---|
Lumit® Detection Substrate B |
VB405A | 1 × 160μl |
Lumit® Detection Buffer B |
VB406A | 1 × 3.2ml |
Anti-hIL-17A mAb-SmBiT, 500X |
W144A | 1 × 30μl |
Anti-hIL-17A mAb-LgBiT, 500X |
W145A | 1 × 30μl |
Human IL-17A Standard |
W143A | 1 × 25μl |
SDS
Search for SDSCertificate of Analysis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Storage Conditions
U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.
U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 10,648,971 and other patents and patents pending.
What's in the box?
Item | Part # | Size |
---|---|---|
Lumit® Detection Substrate B |
VB405B | 1 × 1.25ml |
Lumit® Detection Buffer B |
VB406B | 1 × 25ml |
Anti-hIL-17A mAb-SmBiT, 500X |
W144B | 1 × 300μl |
Anti-hIL-17A mAb-LgBiT, 500X |
W145B | 1 × 300μl |
Human IL-17A Standard |
W143A | 1 × 25μl |
SDS
Search for SDSCertificate of Analysis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Storage Conditions
U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.
U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 10,648,971 and other patents and patents pending.
What's in the box?
Item | Part # | Size |
---|---|---|
Lumit® Detection Substrate B |
VB405A | 5 × 160μl |
Lumit® Detection Buffer B |
VB406A | 5 × 3.2ml |
Anti-hIL-17A mAb-SmBiT, 500X |
W144A | 5 × 30μl |
Anti-hIL-17A mAb-LgBiT, 500X |
W145A | 5 × 30μl |
Human IL-17A Standard |
W143A | 1 × 25μl |
SDS
Search for SDSCertificate of Analysis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Storage Conditions
U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.
U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 10,648,971 and other patents and patents pending.
What's in the box?
Item | Part # | Size |
---|---|---|
Human IL-17A Standard |
W143A | 1 × 25μl |
SDS
Search for SDSCertificate of Analysis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Storage Conditions
Resources
Articles
Posters
Related Products
Similar Products
Lumit® IL-6 (Human) Immunoassay
Quantitatively measures released IL-6 in cell culture samples using a simple, no-wash protocol.
W6030, W6032, W6031, W128A-C
Lumit® IL-1β Human/Mouse Immunoassay
Quantifies inflammasome activation by measuring released IL-1β using a simple, no-wash protocol.
W6010, W6011, W6012, W7010, W7011, W7012, W116A-C, W119A-C
Lumit® TNF-α (Human) Immunoassay
Quantitatively measures released TNF-α in cell culture samples using a simple, no-wash protocol.
W6050, W6052, W6051, W137A-C
Lumit® IFN-γ (Human) Immunoassay
Quantitatively measures released IFN-γ in cell culture samples using a simple, no-wash protocol.
W6040, W6042, W6041, W134A-C
Frequently Used With
Lumit® IL-10 (Human) Immunoassay
Quantitatively measures released IL-10 in cell culture samples using a simple, no-wash protocol.
W6070, W6072, W6071, W131A-C
Lumit® IL-2 (Human) Immunoassay
Quantitatively measures released IL-2 in cell culture samples using a simple, no-wash protocol.
W6020, W6022, W6021, W122A-C
Lumit® IL-4 (Human) Immunoassay
Quantitatively measures released IL-4 in cell culture samples using a simple, no-wash protocol.
W6060, W6062, W6061, W125A-C
GloMax® Discover System
High-performance microplate reader for detecting luminescence, fluorescence and absorbance.
GM3000