NanoBRET® TE Intracellular RAF Dimer Assays
Measure Intracellular Compound Affinity and Occupancy for RAF Kinases in Dimeric Forms
- Quantify compound affinity and fractional occupancy in live cells for full-length ARAF, BRAF and CRAF
- Evaluate target engagement at RAF homodimers (BRAF and CRAF) or at RAF protomers within a RAF heterodimer (ARAF, BRAF and CRAF)
- Ready-to-use assay with a simple, add-and-read workflow
- The 10,000-assay kits for tracer K-4 (N2540) and K-10 (N2840) can be used with RAF Dimer Assay, BC, and RAF Dimer Assay, A, respectively
Assays
Catalog No. | Product Name | Size | Price | Qty | |||
---|---|---|---|---|---|---|---|
N8014 | NanoBRET® TE Intracellular RAF Dimer Assay, BC | View Specifications | 100 assays | List Price: $ 765.00 Your Price: Log In | Add to Cart | ||
N8015 | NanoBRET® TE Intracellular RAF Dimer Assay, BC | View Specifications | 1,000 assays | List Price: $ 4,110.00 Your Price: Log In | Add to Cart | ||
N8016 | NanoBRET® TE Intracellular RAF Dimer Assay, A | View Specifications | 100 assays | List Price: $ 765.00 Your Price: Log In | Add to Cart | ||
N8017 | NanoBRET® TE Intracellular RAF Dimer Assay, A | View Specifications | 1,000 assays | List Price: $ 4,110.00 Your Price: Log In | Add to Cart |
Early Access = This product is available under our Early Access program - Learn More
Catalog (FT) = This product is available under our Catalog (FT) program - Learn More
SmBiT(q) Fusion Vectors
Catalog No. | Product Name | Size | Price | Qty | |||
---|---|---|---|---|---|---|---|
NV4861 | SmBiT(q)-ARAF Fusion Vector | View Specifications | 20μg | List Price: $ 565.00 Your Price: Log In | Add to Cart | ||
NV4871 | BRAF-SmBiT(q) Fusion Vector | View Specifications | 20μg | List Price: $ 565.00 Your Price: Log In | Add to Cart | ||
NV4891 | CRAF-SmBiT(q) Fusion Vector | View Specifications | 20μg | List Price: $ 565.00 Your Price: Log In | Add to Cart | ||
NV4921 | BRAF(A481F)-SmBiT(q) Fusion Vector | View Specifications | 20μg | List Price: $ 565.00 Your Price: Log In | Add to Cart |
Early Access = This product is available under our Early Access program - Learn More
Catalog (FT) = This product is available under our Catalog (FT) program - Learn More
LgBiT Fusion Vectors
Catalog No. | Product Name | Size | Price | Qty | |||
---|---|---|---|---|---|---|---|
NV4881 | BRAF-LgBiT Fusion Vector | View Specifications | 20μg | List Price: $ 565.00 Your Price: Log In | Add to Cart | ||
NV4901 | CRAF-LgBiT Fusion Vector | View Specifications | 20μg | List Price: $ 565.00 Your Price: Log In | Add to Cart | ||
NV4911 | BRAF(A481F)-LgBiT Fusion Vector | View Specifications | 20μg | List Price: $ 565.00 Your Price: Log In | Add to Cart | ||
NV4931 | CRAF(A373F)-LgBiT Fusion Vector | View Specifications | 20μg | List Price: $ 565.00 Your Price: Log In | Add to Cart |
Early Access = This product is available under our Early Access program - Learn More
Catalog (FT) = This product is available under our Catalog (FT) program - Learn More
Expression Vector
Catalog No. | Product Name | Size | Price | Qty | |||
---|---|---|---|---|---|---|---|
NV4941 | KRAS(G12C) Expression Vector | View Specifications | 3 × 20μg | List Price: $ 565.00 Your Price: Log In | Add to Cart |
Early Access = This product is available under our Early Access program - Learn More
Catalog (FT) = This product is available under our Catalog (FT) program - Learn More
Measure Compound Affinity and Occupancy at RAF Dimers in Live Cells
RAF kinases (ARAF, BRAF and CRAF) play an important role in the MAPK signaling pathway, one of the most heavily mutated pathways in cancers. This signaling is typically mediated via the formation of RAF dimers, making these dimers important targets for drug discovery. The NanoBRET® TE Intracellular RAF Dimer Assays can be used to quantify compound affinity and fractional occupancy against RAF kinases in live cells. The assays rely on the NanoBRET® TE technology, a bioluminescence resonance energy transfer (BRET) method that uses a luciferase as the energy donor and a cell-permeable NanoBRET® TE Tracer as the energy acceptor. Instead of using NanoLuc® luciferase-fused target protein as the BRET donor, the NanoBRET® TE Intracellular RAF Dimer Assays use the NanoLuc® Binary Technology (NanoBiT) to enable the measurement of cellular target engagement at RAF dimers.
How the NanoBRET® TE RAF Dimer Assays Work
The NanoBRET® TE Intracellular RAF Dimer Assays use NanoLuc® Binary Technology (NanoBiT), a structural complementation system comprised of a large luciferase subunit (LgBiT) and a small complementary peptide (SmBiT(q)), to evaluate the target engagement of RAF kinases in dimeric complexes. Specifically, a fusion protein of LgBiT and full-length RAF is co-expressed with a fusion protein of SmBiT(q) and full-length RAF in cells. These are co-expressed with the constitutively active mutant KRAS(G12C). When the RAF proteins interact and form dimers in the presence of KRAS(G12C), the LgBiT and SmBiT(q) subunits come together to form an active luciferase enzyme that serves as the BRET donor. The energy acceptor is a cell-permeable fluorescent NanoBRET® tracer that binds specifically to one or both RAF protomers within the complex. Addition of compounds that bind to RAF protomer(s) displaces the tracer and results in a dose-dependent loss of BRET signal.
The NanoBiT® system used in the NanoBRET® TE Intracellular RAF Dimer Assays is unique in the use of the SmBiT(q) peptide, which makes the NanoBiT® luciferase enzyme sensitive to the Extracellular NanoLuc® Inhibitor. This inhibitor quenches signal that can arise from compromised cells and cellular debris to ensure the NanoBRET® signal originates from live cells.
Evaluate Target Engagement at RAF Homodimers and RAF Protomers in RAF Heterodimers
Pairing the appropriate RAF fusion vectors with the recommended assay enables measurement of compound binding to BRAF and CRAF homodimers or to ARAF, BRAF and CRAF protomer within a RAF heterodimeric complex. To evaluate RAF homodimers, transfect cells with LgBiT and SmBiT(q) fusion vectors that express the same RAF protein of interest (Panels A–B and Table). To evaluate a specific RAF protomer within a RAF dimer, the RAF protomer of interest is paired with a second mutant RAF protein (Panels C–E and Table). The mutant RAF proteins contain an alanine-to-phenylalanine mutation that prevent tracer binding to the second RAF protomer but maintain the ability to dimerize with the RAF protomer of interest.
KRAS(G12C) Expression Vector is used with all target assays to drive RAF dimer formation.
Target Assay | SmBiT(q) Fusion Vector | LgBiT Fusion Vector | NanoBRET® TE RAF Dimer Assay |
---|---|---|---|
BRAF Homodimer | BRAF-SmBiT(q) Fusion Vector | BRAF-LgBiT Fusion Vector | BC |
CRAF Homodimer | CRAF-SmBiT(q) Fusion Vector | CRAF-LgBiT Fusion Vector | BC |
ARAF Protomer | SmBiT(q)-ARAF Fusion Vector | BRAF(A481F)-LgBiT Fusion Vector | A |
BRAF Protomer | BRAF-SmBiT(q) Fusion Vector | CRAF(A373F)-LgBiT Fusion Vector | BC |
CRAF Protomer | BRAF(A481F)-SmBiT(q) Fusion Vector | CRAF-LgBiT Fusion Vector | BC |
Profile Compound Activity Across RAF Dimer Variants
Compound activity across multiple RAF configurations. The NanoBRET® TE Intracellular RAF Dimer Assays can be used to evaluate test compound activity across multiple RAF configurations using a similar workflow. Shown here are examples of activity profiles for RAF dimer inhibitor TAK-632 (Panel A) and LXH254 (Panel B). Both inhibitors can engage all RAF dimers, but both compounds show weaker affinity for CRAF within homodimers and for ARAF protomer.
Featured Publication:
Protomer selectivity of type II RAF inhibitors within the RAS/RAF complex
Next-generation RAF inhibitors that inhibit both RAF protomers within a RAF dimer can serve as therapeutics for RAF- and RAS-driven cancers. In this study published in Cell Chemical Biology, NanoBRET® Target Engagement assays were used to quantify target occupancy of RAF dimer inhibitors at selected RAF protomers within an active RAS-RAF complex in live cells. The results show that all inhibitors display reduced affinity for ARAF protomer in live cells. Moreover, ARAF protomer engagement, but not CRAF or BRAF engagement, corresponds with inhibition of RAS-RAF-mediated signaling pathways.
Interested in other assays and technologies targeting the RAS/RAF pathway?
Vector Sequences
Click on the links below to download vector sequences for your RAF variant.
RAF Variant | LgBiT Vector Sequence | SmBiT(q) Vector Sequence |
---|---|---|
ARAF | SmBiT(q)-ARAF Vector Sequence | |
BRAF | BRAF-LgBiT Vector Sequence | BRAF-SmBiT(q) Vector Sequence |
CRAF | CRAF-LgBiT Vector Sequence | CRAF-SmBiT(q) Vector Sequence |
BRAF(A481F) | BRAF(A481F)-LgBiT Vector Sequence | BRAF(A481F)-SmBiT(q) Vector Sequence |
CRAF(A373F) | CRAF(A373F)-LgBiT Vector Sequence | |
KRAS(G12C) Expression Vector | KRAS(G12C) Expression Vector Sequence |
Protocols
Specifications
Catalog Number:
What's in the box?
Item | Part # | Size | Concentration | Available Separately |
---|---|---|---|---|
NanoBRET® Nano-Glo® Substrate |
N157A | 1 × 50μl | View Product | |
Tracer Dilution Buffer |
N219A | 1 × 5ml | View Product | |
Extracellular NanoLuc® Inhibitor |
N235A | 1 × 17μl | View Product | |
NanoBRET® Tracer K-4 |
N249A | 1 × 30μl | 400μM | |
BRAF-SmBiT(q) Fusion Vector |
NV487A | 1 × 20μg | ||
CRAF(A373F)-LgBiT Fusion Vector |
NV493A | 1 × 20μg | ||
KRAS(G12C) Expression Vector |
NV494A | 1 × 20μg |
SDS
Search for SDSCertificate of Analysis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Storage Conditions
NanoBiT® ORF TE Vector Limited Use Label License
BY USE OF THIS PRODUCT, RESEARCHER AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE. If researcher is not willing to accept the terms of this label license, and the product is unused, Promega will accept return of the unused product and provide researcher with a full refund.
Researcher may use this product for research use only; no transfer or commercial use of this product is allowed. Commercial use means any and all uses of this product by a party in exchange for consideration, including, but not limited to (1) use in further product manufacture; (2) use in provision of services, information or data; and (3) resale of the product, whether or not such product is resold for use in research.
Researchers shall have no right to modify or otherwise create variations of the nucleotide sequences of the subunits of NanoBiT® Technology. No other use of this product or its derivatives is authorized without the prior express written consent of Promega.
In addition, researcher must:
(1a) use Nano-Glo®-branded luminescent assay reagents (LARs) for all determinations of luminescence activity of this product; or
(1b) contact Promega to obtain a license for use of the product with LARs not manufactured by Promega.
For uses of this product for energy transfer (such as bioluminescence resonance energy transfer), researcher must:
(2a) use NanoBRET®-branded luminescent assay reagents (LARs; e.g., NanoBRET® Nano-Glo® Substrate), Intracellular TE Nano-Glo® Substrate/Inhibitor or Intracellular TE Nano-Glo® Vivazine®/Inhibitor for all determinations of luminescent activity; and
(2b) use NanoBRET®-branded energy acceptors (e.g., NanoBRET® tracers, NanoBRET® dyes, BRET-optimized HaloTag® ligands) for all determinations of energy transfer activity; or
(2c) contact Promega to obtain a license for use of the product for energy transfer assays using energy acceptors not manufactured by Promega. No license is needed if the energy transfer acceptor is a genetically encoded autofluorescent protein.
With respect to any uses outside this label license, including any diagnostic, therapeutic, prophylactic or commercial uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE PRODUCT. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.
NanoBRET® TE Tracers V2 Limited Use Label License
BY USE OF THIS PRODUCT, RESEARCHER AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE. If researcher is not willing to accept the terms of this label license, and the product is unused, Promega will accept return of the unused product and provide researcher with a full refund.
Researcher may use this product for research use only; no commercial use is allowed. Commercial use means any and all uses of this product by a party in exchange for consideration, including, but not limited to (1) use in further product manufacture; (2) use in provision of services, information or data; and (3) resale of the product, whether or not such product is resold for use in research. Researcher shall have no right to modify or otherwise create variations of the product. No other use or transfer of this product is authorized without the prior express written consent of Promega.
For uses of this product for energy transfer (such as bioluminescence resonance energy transfer), researcher must:
(a) use NanoLuc®-branded luciferase or derivatives, or subunits of the NanoBiT® technology for all energy transfer determinations conducted with this product; and
(b) use NanoBRET®-branded luminescent assay reagents (LARs; e.g., NanoBRET® Nano-Glo® Substrate), Intracellular TE Nano-Glo® Substrate/Inhibitor or Intracellular TE Nano-Glo® Vivazine®/Inhibitor for all determinations of luminescent activity; or
(c) contact Promega to obtain a license for use of the product with LARs not listed above or manufactured by Promega.
In addition, researcher must:
Contact Promega to obtain a license for use of the product in assays not involving bioluminescence resonance energy transfer (BRET).
With respect to any uses outside this label license, including any diagnostic, therapeutic, prophylactic or commercial uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE PRODUCT. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.
NanoBRET® TE LAR Limited Use Label License
BY USE OF THIS PRODUCT, RESEARCHER AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE. If researcher is not willing to accept the terms of this label license, and the product is unused, Promega will accept return of the unused product and provide researcher with a full refund.
Researcher may use this product for research use only; no commercial use is allowed. Commercial use means any and all uses of this product by a party in exchange for consideration, including, but not limited to (1) use in further product manufacture; (2) use in provision of services, information or data; and (3) resale of the product, whether or not such product is resold for use in research. Researcher shall have no right to modify or otherwise create variations of the product. No other use or transfer of this product is authorized without the prior express written consent of Promega.
For uses of this product intended for energy transfer (such as bioluminescence resonance energy transfer) to acceptors other than genetically encoded autofluorescent protein, researcher must:
(i) use NanoBRET®-branded energy acceptors (e.g., NanoBRET® tracers, NanoBRET® dyes, BRET-optimized HaloTag® ligands) for all determinations of energy transfer activity; or
(ii) contact Promega to obtain a license for use of the product for energy transfer assays using energy acceptors not manufactured by Promega.
With respect to any uses outside this label license, including any diagnostic, therapeutic, prophylactic or commercial uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE PRODUCT. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.
U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.
U.S. Pat. Nos. 10,067,149 and 10,024,862, European Pat. No. 2932267, Japanese Pat. Nos. 6751294 and 7092691 and other patents and patents pending.
U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 10,648,971 and other patents and patents pending.
Patent Pending.
Licensed from Kazusa Genome Technologies.
What's in the box?
Item | Part # | Size | Concentration | Available Separately |
---|---|---|---|---|
NanoBRET® Nano-Glo® Substrate |
N157C | 1 × 330μl | View Product | |
Tracer Dilution Buffer |
N219A | 1 × 5ml | View Product | |
Extracellular NanoLuc® Inhibitor |
N235B | 1 × 110μl | View Product | |
NanoBRET® Tracer K-4 |
N249B | 1 × 300μl | 400μM | |
BRAF-SmBiT(q) Fusion Vector |
NV487A | 1 × 20μg | ||
CRAF(A373F)-LgBiT Fusion Vector |
NV493A | 1 × 20μg | ||
KRAS(G12C) Expression Vector |
NV494A | 3 × 20μg |
SDS
Search for SDSCertificate of Analysis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Storage Conditions
NanoBiT® ORF TE Vector Limited Use Label License
BY USE OF THIS PRODUCT, RESEARCHER AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE. If researcher is not willing to accept the terms of this label license, and the product is unused, Promega will accept return of the unused product and provide researcher with a full refund.
Researcher may use this product for research use only; no transfer or commercial use of this product is allowed. Commercial use means any and all uses of this product by a party in exchange for consideration, including, but not limited to (1) use in further product manufacture; (2) use in provision of services, information or data; and (3) resale of the product, whether or not such product is resold for use in research.
Researchers shall have no right to modify or otherwise create variations of the nucleotide sequences of the subunits of NanoBiT® Technology. No other use of this product or its derivatives is authorized without the prior express written consent of Promega.
In addition, researcher must:
(1a) use Nano-Glo®-branded luminescent assay reagents (LARs) for all determinations of luminescence activity of this product; or
(1b) contact Promega to obtain a license for use of the product with LARs not manufactured by Promega.
For uses of this product for energy transfer (such as bioluminescence resonance energy transfer), researcher must:
(2a) use NanoBRET®-branded luminescent assay reagents (LARs; e.g., NanoBRET® Nano-Glo® Substrate), Intracellular TE Nano-Glo® Substrate/Inhibitor or Intracellular TE Nano-Glo® Vivazine®/Inhibitor for all determinations of luminescent activity; and
(2b) use NanoBRET®-branded energy acceptors (e.g., NanoBRET® tracers, NanoBRET® dyes, BRET-optimized HaloTag® ligands) for all determinations of energy transfer activity; or
(2c) contact Promega to obtain a license for use of the product for energy transfer assays using energy acceptors not manufactured by Promega. No license is needed if the energy transfer acceptor is a genetically encoded autofluorescent protein.
With respect to any uses outside this label license, including any diagnostic, therapeutic, prophylactic or commercial uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE PRODUCT. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.
NanoBRET® TE Tracers V2 Limited Use Label License
BY USE OF THIS PRODUCT, RESEARCHER AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE. If researcher is not willing to accept the terms of this label license, and the product is unused, Promega will accept return of the unused product and provide researcher with a full refund.
Researcher may use this product for research use only; no commercial use is allowed. Commercial use means any and all uses of this product by a party in exchange for consideration, including, but not limited to (1) use in further product manufacture; (2) use in provision of services, information or data; and (3) resale of the product, whether or not such product is resold for use in research. Researcher shall have no right to modify or otherwise create variations of the product. No other use or transfer of this product is authorized without the prior express written consent of Promega.
For uses of this product for energy transfer (such as bioluminescence resonance energy transfer), researcher must:
(a) use NanoLuc®-branded luciferase or derivatives, or subunits of the NanoBiT® technology for all energy transfer determinations conducted with this product; and
(b) use NanoBRET®-branded luminescent assay reagents (LARs; e.g., NanoBRET® Nano-Glo® Substrate), Intracellular TE Nano-Glo® Substrate/Inhibitor or Intracellular TE Nano-Glo® Vivazine®/Inhibitor for all determinations of luminescent activity; or
(c) contact Promega to obtain a license for use of the product with LARs not listed above or manufactured by Promega.
In addition, researcher must:
Contact Promega to obtain a license for use of the product in assays not involving bioluminescence resonance energy transfer (BRET).
With respect to any uses outside this label license, including any diagnostic, therapeutic, prophylactic or commercial uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE PRODUCT. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.
NanoBRET® TE LAR Limited Use Label License
BY USE OF THIS PRODUCT, RESEARCHER AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE. If researcher is not willing to accept the terms of this label license, and the product is unused, Promega will accept return of the unused product and provide researcher with a full refund.
Researcher may use this product for research use only; no commercial use is allowed. Commercial use means any and all uses of this product by a party in exchange for consideration, including, but not limited to (1) use in further product manufacture; (2) use in provision of services, information or data; and (3) resale of the product, whether or not such product is resold for use in research. Researcher shall have no right to modify or otherwise create variations of the product. No other use or transfer of this product is authorized without the prior express written consent of Promega.
For uses of this product intended for energy transfer (such as bioluminescence resonance energy transfer) to acceptors other than genetically encoded autofluorescent protein, researcher must:
(i) use NanoBRET®-branded energy acceptors (e.g., NanoBRET® tracers, NanoBRET® dyes, BRET-optimized HaloTag® ligands) for all determinations of energy transfer activity; or
(ii) contact Promega to obtain a license for use of the product for energy transfer assays using energy acceptors not manufactured by Promega.
With respect to any uses outside this label license, including any diagnostic, therapeutic, prophylactic or commercial uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE PRODUCT. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.
U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.
U.S. Pat. Nos. 10,067,149 and 10,024,862, European Pat. No. 2932267, Japanese Pat. Nos. 6751294 and 7092691 and other patents and patents pending.
U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 10,648,971 and other patents and patents pending.
Patent Pending.
Licensed from Kazusa Genome Technologies.
What's in the box?
Item | Part # | Size | Concentration | Available Separately |
---|---|---|---|---|
NanoBRET® Nano-Glo® Substrate |
N157A | 1 × 50μl | View Product | |
Tracer Dilution Buffer |
N219A | 1 × 5ml | View Product | |
Extracellular NanoLuc® Inhibitor |
N235A | 1 × 17μl | View Product | |
NanoBRET® Tracer K-10 |
N264A | 1 × 30μl | 400μM | |
SmBiT(q)-ARAF Fusion Vector |
NV486A | 1 × 20μg | ||
BRAF(A481F)-LgBiT Fusion Vector |
NV491A | 1 × 20μg | ||
KRAS(G12C) Expression Vector |
NV494A | 1 × 20μg |
SDS
Search for SDSCertificate of Analysis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Storage Conditions
NanoBiT® ORF TE Vector Limited Use Label License
BY USE OF THIS PRODUCT, RESEARCHER AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE. If researcher is not willing to accept the terms of this label license, and the product is unused, Promega will accept return of the unused product and provide researcher with a full refund.
Researcher may use this product for research use only; no transfer or commercial use of this product is allowed. Commercial use means any and all uses of this product by a party in exchange for consideration, including, but not limited to (1) use in further product manufacture; (2) use in provision of services, information or data; and (3) resale of the product, whether or not such product is resold for use in research.
Researchers shall have no right to modify or otherwise create variations of the nucleotide sequences of the subunits of NanoBiT® Technology. No other use of this product or its derivatives is authorized without the prior express written consent of Promega.
In addition, researcher must:
(1a) use Nano-Glo®-branded luminescent assay reagents (LARs) for all determinations of luminescence activity of this product; or
(1b) contact Promega to obtain a license for use of the product with LARs not manufactured by Promega.
For uses of this product for energy transfer (such as bioluminescence resonance energy transfer), researcher must:
(2a) use NanoBRET®-branded luminescent assay reagents (LARs; e.g., NanoBRET® Nano-Glo® Substrate), Intracellular TE Nano-Glo® Substrate/Inhibitor or Intracellular TE Nano-Glo® Vivazine®/Inhibitor for all determinations of luminescent activity; and
(2b) use NanoBRET®-branded energy acceptors (e.g., NanoBRET® tracers, NanoBRET® dyes, BRET-optimized HaloTag® ligands) for all determinations of energy transfer activity; or
(2c) contact Promega to obtain a license for use of the product for energy transfer assays using energy acceptors not manufactured by Promega. No license is needed if the energy transfer acceptor is a genetically encoded autofluorescent protein.
With respect to any uses outside this label license, including any diagnostic, therapeutic, prophylactic or commercial uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE PRODUCT. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.
NanoBRET® TE Tracers V2 Limited Use Label License
BY USE OF THIS PRODUCT, RESEARCHER AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE. If researcher is not willing to accept the terms of this label license, and the product is unused, Promega will accept return of the unused product and provide researcher with a full refund.
Researcher may use this product for research use only; no commercial use is allowed. Commercial use means any and all uses of this product by a party in exchange for consideration, including, but not limited to (1) use in further product manufacture; (2) use in provision of services, information or data; and (3) resale of the product, whether or not such product is resold for use in research. Researcher shall have no right to modify or otherwise create variations of the product. No other use or transfer of this product is authorized without the prior express written consent of Promega.
For uses of this product for energy transfer (such as bioluminescence resonance energy transfer), researcher must:
(a) use NanoLuc®-branded luciferase or derivatives, or subunits of the NanoBiT® technology for all energy transfer determinations conducted with this product; and
(b) use NanoBRET®-branded luminescent assay reagents (LARs; e.g., NanoBRET® Nano-Glo® Substrate), Intracellular TE Nano-Glo® Substrate/Inhibitor or Intracellular TE Nano-Glo® Vivazine®/Inhibitor for all determinations of luminescent activity; or
(c) contact Promega to obtain a license for use of the product with LARs not listed above or manufactured by Promega.
In addition, researcher must:
Contact Promega to obtain a license for use of the product in assays not involving bioluminescence resonance energy transfer (BRET).
With respect to any uses outside this label license, including any diagnostic, therapeutic, prophylactic or commercial uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE PRODUCT. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.
NanoBRET® TE LAR Limited Use Label License
BY USE OF THIS PRODUCT, RESEARCHER AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE. If researcher is not willing to accept the terms of this label license, and the product is unused, Promega will accept return of the unused product and provide researcher with a full refund.
Researcher may use this product for research use only; no commercial use is allowed. Commercial use means any and all uses of this product by a party in exchange for consideration, including, but not limited to (1) use in further product manufacture; (2) use in provision of services, information or data; and (3) resale of the product, whether or not such product is resold for use in research. Researcher shall have no right to modify or otherwise create variations of the product. No other use or transfer of this product is authorized without the prior express written consent of Promega.
For uses of this product intended for energy transfer (such as bioluminescence resonance energy transfer) to acceptors other than genetically encoded autofluorescent protein, researcher must:
(i) use NanoBRET®-branded energy acceptors (e.g., NanoBRET® tracers, NanoBRET® dyes, BRET-optimized HaloTag® ligands) for all determinations of energy transfer activity; or
(ii) contact Promega to obtain a license for use of the product for energy transfer assays using energy acceptors not manufactured by Promega.
With respect to any uses outside this label license, including any diagnostic, therapeutic, prophylactic or commercial uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE PRODUCT. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.
U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.
U.S. Pat. Nos. 10,067,149 and 10,024,862, European Pat. No. 2932267, Japanese Pat. Nos. 6751294 and 7092691 and other patents and patents pending.
U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 10,648,971 and other patents and patents pending.
Patent Pending.
Licensed from Kazusa Genome Technologies.
What's in the box?
Item | Part # | Size | Concentration | Available Separately |
---|---|---|---|---|
NanoBRET® Nano-Glo® Substrate |
N157C | 1 × 330μl | View Product | |
Tracer Dilution Buffer |
N219A | 1 × 5ml | View Product | |
Extracellular NanoLuc® Inhibitor |
N235B | 1 × 110μl | View Product | |
NanoBRET® Tracer K-10 |
N264B | 1 × 300μl | 400μM | |
SmBiT(q)-ARAF Fusion Vector |
NV486A | 1 × 20μg | ||
BRAF(A481F)-LgBiT Fusion Vector |
NV491A | 1 × 20μg | ||
KRAS(G12C) Expression Vector |
NV494A | 3 × 20μg |
SDS
Search for SDSCertificate of Analysis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Storage Conditions
NanoBiT® ORF TE Vector Limited Use Label License
BY USE OF THIS PRODUCT, RESEARCHER AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE. If researcher is not willing to accept the terms of this label license, and the product is unused, Promega will accept return of the unused product and provide researcher with a full refund.
Researcher may use this product for research use only; no transfer or commercial use of this product is allowed. Commercial use means any and all uses of this product by a party in exchange for consideration, including, but not limited to (1) use in further product manufacture; (2) use in provision of services, information or data; and (3) resale of the product, whether or not such product is resold for use in research.
Researchers shall have no right to modify or otherwise create variations of the nucleotide sequences of the subunits of NanoBiT® Technology. No other use of this product or its derivatives is authorized without the prior express written consent of Promega.
In addition, researcher must:
(1a) use Nano-Glo®-branded luminescent assay reagents (LARs) for all determinations of luminescence activity of this product; or
(1b) contact Promega to obtain a license for use of the product with LARs not manufactured by Promega.
For uses of this product for energy transfer (such as bioluminescence resonance energy transfer), researcher must:
(2a) use NanoBRET®-branded luminescent assay reagents (LARs; e.g., NanoBRET® Nano-Glo® Substrate), Intracellular TE Nano-Glo® Substrate/Inhibitor or Intracellular TE Nano-Glo® Vivazine®/Inhibitor for all determinations of luminescent activity; and
(2b) use NanoBRET®-branded energy acceptors (e.g., NanoBRET® tracers, NanoBRET® dyes, BRET-optimized HaloTag® ligands) for all determinations of energy transfer activity; or
(2c) contact Promega to obtain a license for use of the product for energy transfer assays using energy acceptors not manufactured by Promega. No license is needed if the energy transfer acceptor is a genetically encoded autofluorescent protein.
With respect to any uses outside this label license, including any diagnostic, therapeutic, prophylactic or commercial uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE PRODUCT. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.
NanoBRET® TE Tracers V2 Limited Use Label License
BY USE OF THIS PRODUCT, RESEARCHER AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE. If researcher is not willing to accept the terms of this label license, and the product is unused, Promega will accept return of the unused product and provide researcher with a full refund.
Researcher may use this product for research use only; no commercial use is allowed. Commercial use means any and all uses of this product by a party in exchange for consideration, including, but not limited to (1) use in further product manufacture; (2) use in provision of services, information or data; and (3) resale of the product, whether or not such product is resold for use in research. Researcher shall have no right to modify or otherwise create variations of the product. No other use or transfer of this product is authorized without the prior express written consent of Promega.
For uses of this product for energy transfer (such as bioluminescence resonance energy transfer), researcher must:
(a) use NanoLuc®-branded luciferase or derivatives, or subunits of the NanoBiT® technology for all energy transfer determinations conducted with this product; and
(b) use NanoBRET®-branded luminescent assay reagents (LARs; e.g., NanoBRET® Nano-Glo® Substrate), Intracellular TE Nano-Glo® Substrate/Inhibitor or Intracellular TE Nano-Glo® Vivazine®/Inhibitor for all determinations of luminescent activity; or
(c) contact Promega to obtain a license for use of the product with LARs not listed above or manufactured by Promega.
In addition, researcher must:
Contact Promega to obtain a license for use of the product in assays not involving bioluminescence resonance energy transfer (BRET).
With respect to any uses outside this label license, including any diagnostic, therapeutic, prophylactic or commercial uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE PRODUCT. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.
NanoBRET® TE LAR Limited Use Label License
BY USE OF THIS PRODUCT, RESEARCHER AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE. If researcher is not willing to accept the terms of this label license, and the product is unused, Promega will accept return of the unused product and provide researcher with a full refund.
Researcher may use this product for research use only; no commercial use is allowed. Commercial use means any and all uses of this product by a party in exchange for consideration, including, but not limited to (1) use in further product manufacture; (2) use in provision of services, information or data; and (3) resale of the product, whether or not such product is resold for use in research. Researcher shall have no right to modify or otherwise create variations of the product. No other use or transfer of this product is authorized without the prior express written consent of Promega.
For uses of this product intended for energy transfer (such as bioluminescence resonance energy transfer) to acceptors other than genetically encoded autofluorescent protein, researcher must:
(i) use NanoBRET®-branded energy acceptors (e.g., NanoBRET® tracers, NanoBRET® dyes, BRET-optimized HaloTag® ligands) for all determinations of energy transfer activity; or
(ii) contact Promega to obtain a license for use of the product for energy transfer assays using energy acceptors not manufactured by Promega.
With respect to any uses outside this label license, including any diagnostic, therapeutic, prophylactic or commercial uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE PRODUCT. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.
U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.
U.S. Pat. Nos. 10,067,149 and 10,024,862, European Pat. No. 2932267, Japanese Pat. Nos. 6751294 and 7092691 and other patents and patents pending.
U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 10,648,971 and other patents and patents pending.
Patent Pending.
Licensed from Kazusa Genome Technologies.
What's in the box?
Item | Part # | Size |
---|---|---|
SmBiT(q)-ARAF Fusion Vector |
NV486A | 1 × 20μg |
SDS
Search for SDSCertificate of Analysis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Storage Conditions
NanoBiT® ORF TE Vector Limited Use Label License
BY USE OF THIS PRODUCT, RESEARCHER AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE. If researcher is not willing to accept the terms of this label license, and the product is unused, Promega will accept return of the unused product and provide researcher with a full refund.
Researcher may use this product for research use only; no transfer or commercial use of this product is allowed. Commercial use means any and all uses of this product by a party in exchange for consideration, including, but not limited to (1) use in further product manufacture; (2) use in provision of services, information or data; and (3) resale of the product, whether or not such product is resold for use in research.
Researchers shall have no right to modify or otherwise create variations of the nucleotide sequences of the subunits of NanoBiT® Technology. No other use of this product or its derivatives is authorized without the prior express written consent of Promega.
In addition, researcher must:
(1a) use Nano-Glo®-branded luminescent assay reagents (LARs) for all determinations of luminescence activity of this product; or
(1b) contact Promega to obtain a license for use of the product with LARs not manufactured by Promega.
For uses of this product for energy transfer (such as bioluminescence resonance energy transfer), researcher must:
(2a) use NanoBRET®-branded luminescent assay reagents (LARs; e.g., NanoBRET® Nano-Glo® Substrate), Intracellular TE Nano-Glo® Substrate/Inhibitor or Intracellular TE Nano-Glo® Vivazine®/Inhibitor for all determinations of luminescent activity; and
(2b) use NanoBRET®-branded energy acceptors (e.g., NanoBRET® tracers, NanoBRET® dyes, BRET-optimized HaloTag® ligands) for all determinations of energy transfer activity; or
(2c) contact Promega to obtain a license for use of the product for energy transfer assays using energy acceptors not manufactured by Promega. No license is needed if the energy transfer acceptor is a genetically encoded autofluorescent protein.
With respect to any uses outside this label license, including any diagnostic, therapeutic, prophylactic or commercial uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE PRODUCT. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.
Licensed from Kazusa Genome Technologies.
What's in the box?
Item | Part # | Size |
---|---|---|
BRAF-SmBiT(q) Fusion Vector |
NV487A | 1 × 20μg |
SDS
Search for SDSCertificate of Analysis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Storage Conditions
NanoBiT® ORF TE Vector Limited Use Label License
BY USE OF THIS PRODUCT, RESEARCHER AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE. If researcher is not willing to accept the terms of this label license, and the product is unused, Promega will accept return of the unused product and provide researcher with a full refund.
Researcher may use this product for research use only; no transfer or commercial use of this product is allowed. Commercial use means any and all uses of this product by a party in exchange for consideration, including, but not limited to (1) use in further product manufacture; (2) use in provision of services, information or data; and (3) resale of the product, whether or not such product is resold for use in research.
Researchers shall have no right to modify or otherwise create variations of the nucleotide sequences of the subunits of NanoBiT® Technology. No other use of this product or its derivatives is authorized without the prior express written consent of Promega.
In addition, researcher must:
(1a) use Nano-Glo®-branded luminescent assay reagents (LARs) for all determinations of luminescence activity of this product; or
(1b) contact Promega to obtain a license for use of the product with LARs not manufactured by Promega.
For uses of this product for energy transfer (such as bioluminescence resonance energy transfer), researcher must:
(2a) use NanoBRET®-branded luminescent assay reagents (LARs; e.g., NanoBRET® Nano-Glo® Substrate), Intracellular TE Nano-Glo® Substrate/Inhibitor or Intracellular TE Nano-Glo® Vivazine®/Inhibitor for all determinations of luminescent activity; and
(2b) use NanoBRET®-branded energy acceptors (e.g., NanoBRET® tracers, NanoBRET® dyes, BRET-optimized HaloTag® ligands) for all determinations of energy transfer activity; or
(2c) contact Promega to obtain a license for use of the product for energy transfer assays using energy acceptors not manufactured by Promega. No license is needed if the energy transfer acceptor is a genetically encoded autofluorescent protein.
With respect to any uses outside this label license, including any diagnostic, therapeutic, prophylactic or commercial uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE PRODUCT. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.
Licensed from Kazusa Genome Technologies.
What's in the box?
Item | Part # | Size |
---|---|---|
BRAF-LgBiT Fusion Vector |
NV488A | 1 × 20μg |
SDS
Search for SDSCertificate of Analysis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Storage Conditions
NanoBiT® ORF TE Vector Limited Use Label License
BY USE OF THIS PRODUCT, RESEARCHER AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE. If researcher is not willing to accept the terms of this label license, and the product is unused, Promega will accept return of the unused product and provide researcher with a full refund.
Researcher may use this product for research use only; no transfer or commercial use of this product is allowed. Commercial use means any and all uses of this product by a party in exchange for consideration, including, but not limited to (1) use in further product manufacture; (2) use in provision of services, information or data; and (3) resale of the product, whether or not such product is resold for use in research.
Researchers shall have no right to modify or otherwise create variations of the nucleotide sequences of the subunits of NanoBiT® Technology. No other use of this product or its derivatives is authorized without the prior express written consent of Promega.
In addition, researcher must:
(1a) use Nano-Glo®-branded luminescent assay reagents (LARs) for all determinations of luminescence activity of this product; or
(1b) contact Promega to obtain a license for use of the product with LARs not manufactured by Promega.
For uses of this product for energy transfer (such as bioluminescence resonance energy transfer), researcher must:
(2a) use NanoBRET®-branded luminescent assay reagents (LARs; e.g., NanoBRET® Nano-Glo® Substrate), Intracellular TE Nano-Glo® Substrate/Inhibitor or Intracellular TE Nano-Glo® Vivazine®/Inhibitor for all determinations of luminescent activity; and
(2b) use NanoBRET®-branded energy acceptors (e.g., NanoBRET® tracers, NanoBRET® dyes, BRET-optimized HaloTag® ligands) for all determinations of energy transfer activity; or
(2c) contact Promega to obtain a license for use of the product for energy transfer assays using energy acceptors not manufactured by Promega. No license is needed if the energy transfer acceptor is a genetically encoded autofluorescent protein.
With respect to any uses outside this label license, including any diagnostic, therapeutic, prophylactic or commercial uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE PRODUCT. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.
Licensed from Kazusa Genome Technologies.
What's in the box?
Item | Part # | Size |
---|---|---|
CRAF-SmBiT(q) Fusion Vector |
NV489A | 1 × 20μg |
SDS
Search for SDSCertificate of Analysis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Storage Conditions
NanoBiT® ORF TE Vector Limited Use Label License
BY USE OF THIS PRODUCT, RESEARCHER AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE. If researcher is not willing to accept the terms of this label license, and the product is unused, Promega will accept return of the unused product and provide researcher with a full refund.
Researcher may use this product for research use only; no transfer or commercial use of this product is allowed. Commercial use means any and all uses of this product by a party in exchange for consideration, including, but not limited to (1) use in further product manufacture; (2) use in provision of services, information or data; and (3) resale of the product, whether or not such product is resold for use in research.
Researchers shall have no right to modify or otherwise create variations of the nucleotide sequences of the subunits of NanoBiT® Technology. No other use of this product or its derivatives is authorized without the prior express written consent of Promega.
In addition, researcher must:
(1a) use Nano-Glo®-branded luminescent assay reagents (LARs) for all determinations of luminescence activity of this product; or
(1b) contact Promega to obtain a license for use of the product with LARs not manufactured by Promega.
For uses of this product for energy transfer (such as bioluminescence resonance energy transfer), researcher must:
(2a) use NanoBRET®-branded luminescent assay reagents (LARs; e.g., NanoBRET® Nano-Glo® Substrate), Intracellular TE Nano-Glo® Substrate/Inhibitor or Intracellular TE Nano-Glo® Vivazine®/Inhibitor for all determinations of luminescent activity; and
(2b) use NanoBRET®-branded energy acceptors (e.g., NanoBRET® tracers, NanoBRET® dyes, BRET-optimized HaloTag® ligands) for all determinations of energy transfer activity; or
(2c) contact Promega to obtain a license for use of the product for energy transfer assays using energy acceptors not manufactured by Promega. No license is needed if the energy transfer acceptor is a genetically encoded autofluorescent protein.
With respect to any uses outside this label license, including any diagnostic, therapeutic, prophylactic or commercial uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE PRODUCT. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.
Licensed from Kazusa Genome Technologies.
What's in the box?
Item | Part # | Size |
---|---|---|
CRAF-LgBiT Fusion Vector |
NV490A | 1 × 20μg |
SDS
Search for SDSCertificate of Analysis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Storage Conditions
NanoBiT® ORF TE Vector Limited Use Label License
BY USE OF THIS PRODUCT, RESEARCHER AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE. If researcher is not willing to accept the terms of this label license, and the product is unused, Promega will accept return of the unused product and provide researcher with a full refund.
Researcher may use this product for research use only; no transfer or commercial use of this product is allowed. Commercial use means any and all uses of this product by a party in exchange for consideration, including, but not limited to (1) use in further product manufacture; (2) use in provision of services, information or data; and (3) resale of the product, whether or not such product is resold for use in research.
Researchers shall have no right to modify or otherwise create variations of the nucleotide sequences of the subunits of NanoBiT® Technology. No other use of this product or its derivatives is authorized without the prior express written consent of Promega.
In addition, researcher must:
(1a) use Nano-Glo®-branded luminescent assay reagents (LARs) for all determinations of luminescence activity of this product; or
(1b) contact Promega to obtain a license for use of the product with LARs not manufactured by Promega.
For uses of this product for energy transfer (such as bioluminescence resonance energy transfer), researcher must:
(2a) use NanoBRET®-branded luminescent assay reagents (LARs; e.g., NanoBRET® Nano-Glo® Substrate), Intracellular TE Nano-Glo® Substrate/Inhibitor or Intracellular TE Nano-Glo® Vivazine®/Inhibitor for all determinations of luminescent activity; and
(2b) use NanoBRET®-branded energy acceptors (e.g., NanoBRET® tracers, NanoBRET® dyes, BRET-optimized HaloTag® ligands) for all determinations of energy transfer activity; or
(2c) contact Promega to obtain a license for use of the product for energy transfer assays using energy acceptors not manufactured by Promega. No license is needed if the energy transfer acceptor is a genetically encoded autofluorescent protein.
With respect to any uses outside this label license, including any diagnostic, therapeutic, prophylactic or commercial uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE PRODUCT. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.
Licensed from Kazusa Genome Technologies.
What's in the box?
Item | Part # | Size |
---|---|---|
BRAF(A481F)-LgBiT Fusion Vector |
NV491A | 1 × 20μg |
SDS
Search for SDSCertificate of Analysis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Storage Conditions
NanoBiT® ORF TE Vector Limited Use Label License
BY USE OF THIS PRODUCT, RESEARCHER AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE. If researcher is not willing to accept the terms of this label license, and the product is unused, Promega will accept return of the unused product and provide researcher with a full refund.
Researcher may use this product for research use only; no transfer or commercial use of this product is allowed. Commercial use means any and all uses of this product by a party in exchange for consideration, including, but not limited to (1) use in further product manufacture; (2) use in provision of services, information or data; and (3) resale of the product, whether or not such product is resold for use in research.
Researchers shall have no right to modify or otherwise create variations of the nucleotide sequences of the subunits of NanoBiT® Technology. No other use of this product or its derivatives is authorized without the prior express written consent of Promega.
In addition, researcher must:
(1a) use Nano-Glo®-branded luminescent assay reagents (LARs) for all determinations of luminescence activity of this product; or
(1b) contact Promega to obtain a license for use of the product with LARs not manufactured by Promega.
For uses of this product for energy transfer (such as bioluminescence resonance energy transfer), researcher must:
(2a) use NanoBRET®-branded luminescent assay reagents (LARs; e.g., NanoBRET® Nano-Glo® Substrate), Intracellular TE Nano-Glo® Substrate/Inhibitor or Intracellular TE Nano-Glo® Vivazine®/Inhibitor for all determinations of luminescent activity; and
(2b) use NanoBRET®-branded energy acceptors (e.g., NanoBRET® tracers, NanoBRET® dyes, BRET-optimized HaloTag® ligands) for all determinations of energy transfer activity; or
(2c) contact Promega to obtain a license for use of the product for energy transfer assays using energy acceptors not manufactured by Promega. No license is needed if the energy transfer acceptor is a genetically encoded autofluorescent protein.
With respect to any uses outside this label license, including any diagnostic, therapeutic, prophylactic or commercial uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE PRODUCT. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.
Licensed from Kazusa Genome Technologies.
What's in the box?
Item | Part # | Size |
---|---|---|
BRAF(A481F)-SmBiT(q) Fusion Vector |
NV492A | 1 × 20μg |
SDS
Search for SDSCertificate of Analysis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Storage Conditions
NanoBiT® ORF TE Vector Limited Use Label License
BY USE OF THIS PRODUCT, RESEARCHER AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE. If researcher is not willing to accept the terms of this label license, and the product is unused, Promega will accept return of the unused product and provide researcher with a full refund.
Researcher may use this product for research use only; no transfer or commercial use of this product is allowed. Commercial use means any and all uses of this product by a party in exchange for consideration, including, but not limited to (1) use in further product manufacture; (2) use in provision of services, information or data; and (3) resale of the product, whether or not such product is resold for use in research.
Researchers shall have no right to modify or otherwise create variations of the nucleotide sequences of the subunits of NanoBiT® Technology. No other use of this product or its derivatives is authorized without the prior express written consent of Promega.
In addition, researcher must:
(1a) use Nano-Glo®-branded luminescent assay reagents (LARs) for all determinations of luminescence activity of this product; or
(1b) contact Promega to obtain a license for use of the product with LARs not manufactured by Promega.
For uses of this product for energy transfer (such as bioluminescence resonance energy transfer), researcher must:
(2a) use NanoBRET®-branded luminescent assay reagents (LARs; e.g., NanoBRET® Nano-Glo® Substrate), Intracellular TE Nano-Glo® Substrate/Inhibitor or Intracellular TE Nano-Glo® Vivazine®/Inhibitor for all determinations of luminescent activity; and
(2b) use NanoBRET®-branded energy acceptors (e.g., NanoBRET® tracers, NanoBRET® dyes, BRET-optimized HaloTag® ligands) for all determinations of energy transfer activity; or
(2c) contact Promega to obtain a license for use of the product for energy transfer assays using energy acceptors not manufactured by Promega. No license is needed if the energy transfer acceptor is a genetically encoded autofluorescent protein.
With respect to any uses outside this label license, including any diagnostic, therapeutic, prophylactic or commercial uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE PRODUCT. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.
Licensed from Kazusa Genome Technologies.
What's in the box?
Item | Part # | Size |
---|---|---|
CRAF(A373F)-LgBiT Fusion Vector |
NV493A | 1 × 20μg |
SDS
Search for SDSCertificate of Analysis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Storage Conditions
NanoBiT® ORF TE Vector Limited Use Label License
BY USE OF THIS PRODUCT, RESEARCHER AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE. If researcher is not willing to accept the terms of this label license, and the product is unused, Promega will accept return of the unused product and provide researcher with a full refund.
Researcher may use this product for research use only; no transfer or commercial use of this product is allowed. Commercial use means any and all uses of this product by a party in exchange for consideration, including, but not limited to (1) use in further product manufacture; (2) use in provision of services, information or data; and (3) resale of the product, whether or not such product is resold for use in research.
Researchers shall have no right to modify or otherwise create variations of the nucleotide sequences of the subunits of NanoBiT® Technology. No other use of this product or its derivatives is authorized without the prior express written consent of Promega.
In addition, researcher must:
(1a) use Nano-Glo®-branded luminescent assay reagents (LARs) for all determinations of luminescence activity of this product; or
(1b) contact Promega to obtain a license for use of the product with LARs not manufactured by Promega.
For uses of this product for energy transfer (such as bioluminescence resonance energy transfer), researcher must:
(2a) use NanoBRET®-branded luminescent assay reagents (LARs; e.g., NanoBRET® Nano-Glo® Substrate), Intracellular TE Nano-Glo® Substrate/Inhibitor or Intracellular TE Nano-Glo® Vivazine®/Inhibitor for all determinations of luminescent activity; and
(2b) use NanoBRET®-branded energy acceptors (e.g., NanoBRET® tracers, NanoBRET® dyes, BRET-optimized HaloTag® ligands) for all determinations of energy transfer activity; or
(2c) contact Promega to obtain a license for use of the product for energy transfer assays using energy acceptors not manufactured by Promega. No license is needed if the energy transfer acceptor is a genetically encoded autofluorescent protein.
With respect to any uses outside this label license, including any diagnostic, therapeutic, prophylactic or commercial uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE PRODUCT. The terms of this label license shall be governed under the laws of the State of Wisconsin, USA.
Licensed from Kazusa Genome Technologies.
What's in the box?
Item | Part # | Size |
---|---|---|
KRAS(G12C) Expression Vector |
NV494A | 3 × 20μg |
SDS
Search for SDSCertificate of Analysis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Storage Conditions
Licensed from Kazusa Genome Technologies.
Related Products
Similar Products
RAS Pathway Knock-In Cell Lines
Study the abundance and degradation of endogenous proteins involved in critical signaling pathways, such as the RAS-RAF-MEK-ERK cascade.
NanoBRET® TE Intracellular RAS Assay
A novel method for studying RAS using BRET technology.
N8010, N8012, N8013, NV4561, NV4571, NV4581, NV4591, NV4601, NV4611, NV4621, NV4631, NV4641, NV4651, NV4661, NV4671, NV4681, NV4691, NV4701, NV4711, NV4721, NV4731, NV4741, NV4751, NV4761, NV4771, NV4781, NV4791, NV4801, NV4811, NV4821, NV4831, NV4841, NV4851
NanoBRET® Target Engagement Kinase Assays
Directly measure kinase-ligand binding affinity, occupancy and residence time in live cells.
N2520, N2521, N2540, N2501, N2500, N2530, N2600, N2601, N2620, N2621, N2630, N2631, N2640, N2641, N2650, N2651, NF1001, N2810, N2820, N2830, N2840, N2850, NF1200
NanoBRET® Target Engagement HDAC Assays
Directly measure HDAC-test compound affinity and residence time in live cells.
N2080, N2081, N2170, N2090
NanoBRET® Target Engagement BET BRD Assays
Directly measure BET bromodomain-test compound affinity and residence time in live cells.
N2131, N2180, N2130, N2140
NanoBRET® TE Intracellular E3 Ligase Assays
Measure compound binding or affinity for an E3 ubiquitin ligase protein, CRBN or VHL, in live cells.
N2910, N2911, N2912, N2930, N2931, N2932, CS1810E20, CS1810E21, CS1810E23, CS1810E24
Frequently Used With
Intracellular TE Nano-Glo® Substrate/Inhibitor
The recommended NanoLuc® substrate and extracellular inhibitor for NanoBRET® Target Engagement Intracellular Assays.
N2162, N2160, N2161
Cell-Permeable Kinase NanoBRET® TE Tracers
A NanoBRET® TE Tracer is composed of a biologically active small molecule or inhibitor of a target protein that is covalently conjugated to a fluorescent dye.
N2602, N2482, N2492, N2622, N2632, N2642, N2652, NF1011
FuGENE® HD Transfection Reagent
Enhanced performance in a range of cell types, including difficult-to-transfect cell lines.
E2311, E2312
GloMax® Discover System
High-performance microplate reader for detecting luminescence, fluorescence and absorbance.
GM3000