PowerPlex® 35GY System

customize-this-small
View information on global supply logistics

The First 8-Dye PowerPlex® STR Multiplex System

  • Rapid cycling conditions for extracted DNA and database samples
  • Consists of Amelogenin, 23 autosomal STR loci, 11 Y-STR loci and two quality indicators in a single multiplex
  • Fifteen of the autosomal STR loci are less than 250bp
  • Optimized for use with the Spectrum CE and Spectrum Compact CE Systems

Choose a product

Size

Catalog number selected: DC3520

Your price:
Add to Cart
This product is discontinued
This product is available under our Early Access program - Learn More
This product is available under our Catalog (FT) program - Learn More
PowerPlex® 35GY System
PowerPlex® 35GY System/200 (or 400 direct-amp) reactions
Your price: Log in
Change Configuration

More Information from Your Sample

The PowerPlex® 35GY System is the first 8-dye STR multiplex and allows co-amplification and fluorescent detection of the 20 CODIS core loci plus Amelogenin and DYS391 for sex determination. The inclusion of two additional dye channels relative to previous STR multiplex kits provides improved and more informative analyses for even your most challenging DNA samples.

  • Fifteen mini-STRs improve results with degraded samples.
  • System contains the shortest SE33 amplicon of any STR chemistry kit available.
  • Penta D, Penta E and SE33 loci allow wider database searching.
  • The PowerPlex® 35GY QI Reagent is required for direct amplification and assists in determining if a sample is degraded or inhibited.
Read the article on developmental validation of the PowerPlex® 35GY System in Forensic Genomics.

The Most Loci in Any STR Multiplex

PowerPlex® 35GY System loci

The power of 8 dye channels. Shifting larger autosomal loci in the PowerPlex® Fusion 6C System into two additional dye channels in the PowerPlex® 35GY System frees up space for Y-STR loci to be included, providing more information from a sample and improving analysis.


One Kit for All Your Sample Types

Designed for amplification of extracted DNA and direct amplification of single-source reference samples, the PowerPlex® 35GY System enables laboratories to process all sample types with one amplification kit. The PowerPlex® 35GY System is optimized to work with 1ng of extracted DNA in a 25μl reaction volume and is compatible with the Spectrum CE System and Spectrum Compact CE System.

2800M Control DNA–Spectrum CE System

Electropherogram of extracted DNA amplified using the PowerPlex® 35GY System.

Amplifying extracted DNA with the PowerPlex® 35GY System. The 2800M Control DNA (1ng) was amplified using the PowerPlex® 35GY System. Amplification products were mixed with CCO Internal Lane Standard 500 and separated on the Spectrum CE System. The electropherogram was generated using GeneMarker® HID Software for Spectrum CE Systems. Dye names are shown on the right.

2800M Control DNA–Spectrum Compact CE System

18690ta-b

Amplifying Extracted DNA with the PowerPlex® 35GY System. The 2800M Control DNA (1ng) was amplified using the PowerPlex® 35GY System. Amplification products were mixed with CCO Internal Lane Standard 500 and separated on the Spectrum Compact CE System. The electropherogram was generated using GeneMarker® HID Software for Spectrum CE Systems.


As with our 5-dye and 6-dye PowerPlex® Systems, the PowerPlex® 35GY System also supports reduced-volume direct amplification reactions. In one example, DNA from a buccal swab in SwabSolution™ Reagent was amplified for 25 cycles in a 12.5μl reaction volume. Amplified samples were separated on the Spectrum CE System.

Buccal FTA® Punch

Electropherogram of buccal cells direct-amplified using the PowerPlex® 35GY System.

Direct amplification with the PowerPlex® 35GY System. An FTA® punch of buccal cells was direct-amplified using the PowerPlex® 35GY System. Amplification products were separated on the Spectrum CE System and analyzed using GeneMarker® HID Software for Spectrum CE Systems.


Quality Indicators Ease Data Interpretation

To help you better interpret the quality of your STR results, the PowerPlex® 35GY System is the first PowerPlex® system to include two Quality Indicators, QIS and QIL. The Quality Indicators take the guesswork out of determining if amplification was successful by confirming if DNA is present or if the sample amplification was inhibited. Knowing whether a sample was degraded or inhibited lets you decide whether to repeat sample analysis.

At-a-Glance Quality Analysis

Electropherogram showing quality indicators for the PowerPlex® 35GY System.

Quality indicators for the PowerPlex® 35GY System. Balanced QIS and QIL peaks indicate a successful STR profile (Panel A). An STR profile with balanced QIS and QIL peaks but no STR peaks indicates that no template DNA was amplified (Panel B). A sloping STR profile with balanced QIS and QIL peaks signals degraded sample (Panel C). A sloping STR profile with a low or missing QIL peak suggests the sample is inhibited (Panel D).


More Successful Mixture Deconvolution

Mixed casework samples often contain PCR inhibitors, and the minor DNA component may be present at a very low level. The enhanced sensitivity and superior capability to overcome inhibition, as well as inclusion of 11 Y-STR loci in the PowerPlex® 35GY System, enable laboratories to interpret mixed samples more confidently than previously possible.

M:M:M:F - 4:3:2:1

Electropherogram of extracted DNA from 4-person mixtures amplified using the PowerPlex® 35GY System.

Better mixture analysis with more Y-STRs in the PowerPlex® 35GY System. Extracted DNA (1ng) from four-person mixtures was amplified using the PowerPlex® 35GY System. Amplification products were separated on the Spectrum CE System and analyzed using GeneMarker® HID Software for Spectrum CE Systems.


Mini-STRs Improve Success with Difficult Samples

The environmental conditions encountered in forensic casework, mass disasters and missing persons scenarios can lead to severe degradation of human DNA samples. Such highly degraded samples often produce incomplete or no STR profiles due to larger loci that can “drop out”. The inclusion of more loci as mini-STRs in the PowerPlex® 35GY System results in better and more complete profiles, making this system an ideal option to process cold-case samples and newer, difficult sample types.

In the PowerPlex® 35GY System, there are eight common loci with amplicons that are at least 100bp smaller in size than when amplified using the PowerPlex® Fusion 6C System.


35gy-product-page-bones
ForensicGrade

Promega forensic products are manufactured in alignment with the ISO 18385 standard. This standard ensures minimal risk of human DNA contamination for products used to collect, store and analyze biological materials for forensic purposes. Learn more.

Specifications

You are viewing: DC3520 Change Configuration

What's in the box?

Item Part # Size Concentration Available Separately

2800M Control DNA

DD710A 1 × 25μl 10ng/μl View Product

PowerPlex® 35GY 5X Primer Pair Mix

DK481B 1 × 1ml

PowerPlex® 35GY 5X Master Mix

DP800A 1 × 1ml

Water, Amplification Grade

DW099A 5 × 1,250μl View Product

CCO Internal Lane Standard 500

DG857A 1 × 250μl

PowerPlex® 35GY Allelic Ladder Mix

DG853B 1 × 100μl

Certificate of Analysis

Search by lot number

Use Restrictions

Not For Medical Diagnostic Use.

Storage Conditions

CC

Specifications

You are viewing: DG5010 Change Configuration

What's in the box?

Item Part # Size

8C Matrix Mix

DG854A 1 × 150μl

Matrix Dilution Buffer

DM145A 5 × 200μl

Certificate of Analysis

Search by lot number

Use Restrictions

Not For Medical Diagnostic Use.

Storage Conditions

CC

Specifications

You are viewing: DM1551 Change Configuration

What's in the box?

Item Part # Size

PowerPlex® 35GY QI Reagent

DM155A 1 × 800μl

Certificate of Analysis

Search by lot number

Use Restrictions

Not For Medical Diagnostic Use.

Storage Conditions

CC

Specifications

You are viewing: DG8571 Change Configuration

What's in the box?

Item Part # Size

CCO Internal Lane Standard 500

DG857A 1 × 250μl

Certificate of Analysis

Search by lot number

Use Restrictions

Not For Medical Diagnostic Use.

Storage Conditions

CC

Let's find the product that meets your needs.

Talk to a Scientist

Robert

Robert

US