Starting a new lab? Save 50% when you register for our New Lab Startup Program. Sign Up Today ›

pFN31 and pFC32 NanoLuc® Protein Fusion Flexi® Vectors

customize-this-small
View information on global supply logistics

Generate N- or C-Terminal Fusions to NanoLuc® Luciferase Reporter

  • Insert protein of interest using the Flexi® Vector System
  • Select options for N- or C-terminal NanoLuc® fusions and antibiotic resistance (ampicillin or kanamycin)
  • Bright NanoLuc® reporter enables endogenous expression levels of fusion proteins for biologically relevant results

Choose a protein fusion and antibiotic resistance

Size

Catalog number selected: N1311

$ 314.00
Your price:
Add to Cart
This product is discontinued
Add to Helix
This product is available under our Early Access program - Learn More
This product is available under our Catalog (FT) program - Learn More
pFN31 and pFC32 NanoLuc® Protein Fusion Flexi® Vectors
N-terminal + Ampicillin/20µg
$ 314.00
Your price: Log in
Change Configuration

Generate N-terminal fusions with NanoLuc® luciferase using the pFN31A and pFN31K Nluc CMV-neo Flexi® Vectors while the pFC32A and pFC32K Nluc CMV-neo Flexi® Vectors create C-terminal Nluc fusion proteins. These vectors are part of the Flexi® Vector Cloning System that uses a directional cloning method based on two rare-cutting restriction enzymes, SgfI and PmeI, that provides a rapid, efficient and high-fidelity way to transfer protein-coding regions between a variety of Flexi® Vectors without the need to resequence. All vectors contain a mammalian selectable marker to create a stable line.

The small size (19.1kDa) and extreme brightness of NanoLuc® luciferase (Nluc; about 100-fold brighter than either firefly [Photinus pyralis] or Renilla reniformis) make it an ideal protein fusion partner. When visualizing intracellular protein dynamics, the bright NanoLuc® reporter reduces imaging exposure times without the need for repeated sample excitation, which can result in cytotoxic artifacts.

NanoLuc® fusion proteins can be used in a variety of applications including: reporters of protein stability, probes for bioluminescent cell imaging (BLI) or as the donor signal in bioluminescent resonance energy transfer (BRET) applications for protein:protein or protein:small-molecule interaction studies. The brighter signal and blue-shifted emission spectrum from NanoLuc® luciferase result in less spectral overlap with fluorescent acceptors, resulting in better signal:background and dynamic range for BRET applications.

Additional NanoLuc® protein fusion vectors include the pNLF Vector series. Generate N- or C-terminal fusions to the full-length Nluc protein or attach secreted Nluc to the N-terminus of the protein of interest using traditional cloning with a multiple cloning site (MCS).

Applications

  • Compound screening.
  • Protein:protein interactions.
  • Protein:small-molecule interactions.
  • Bioluminescent imaging.
  • Protein stability.

Reference

  1. Hall, M.P. (2012) Engineered luciferase reporter from a deep sea shrimp utilizing a novel imidazopyrazinone substrate. ACS Chemical Biology 7(11), 1848–57.

Sequence Information

pFN31A Nluc CMV-Hygro Flexi® Vector GenBank® Accession Number KF793052 and vector sequence text file.

pFN31K Nluc CMV-neo Flexi® Vector GenBank® Accession Number KF793053 and vector sequence text file.

pFC32A Nluc CMV-Hygro Flexi® Vector GenBank® Accession Number KF811455 and vector sequence text file.

pFC32K Nluc CMV-neo Flexi® Vector GenBank® Accession Number KF811456  and vector sequence text file.

Specifications

You are viewing: N1311 Change Configuration

What's in the box?

Item Part # Size Concentration

pFN31A Nluc CMV-Hygro Flexi® Vector

N131A 1 × 20μg 0.1μg/μl

Certificate of Analysis

Search by lot number

Use Restrictions

For Research Use Only. Not for Use in Diagnostic Procedures.

Storage Conditions

BB

Patents and Disclaimers

BY USE OF THIS PRODUCT, RESEARCHER AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE. If researcher is not willing to accept the conditions of this limited use statement, and the product is unused, Promega will accept return of the unused product and provide researcher with a full refund.

Researchers may use this product for research use only; no transfer or commercial use of this product is allowed. Commercial use means any and all uses of this product or derivatives by a party in exchange for consideration, including, but not limited to (1) use in further product manufacture; (2) use in provision of services, information or data; and (3) resale of the product or its derivatives, whether or not such product or derivatives are resold for use in research. Researchers shall have no right to modify or otherwise create variations of the nucleotide sequence of the luciferase gene except that researcher may (1) create fused gene sequences provided that the coding sequence of the resulting luciferase gene has no more than four deoxynucleotides missing at the affected terminus compared to the intact luciferase gene sequence; and (2) insert and remove nucleic acid sequences in splicing research predicated on the inactivation or reconstitution of the luminescence of the encoded luciferase. No other use of this product or derivatives is authorized without the prior express written consent of Promega.

In addition, researchers must:
(1a) use Nano-Glo®-branded luminescent assay reagents (LARs) for all determinations of luminescence activity of this product and its derivatives; or
(1b) contact Promega to obtain a license for use of the product and its derivatives with LARs not manufactured by Promega.

For uses of Nano-Glo®-branded LARs intended for energy transfer (such as bioluminescence resonance energy transfer) to acceptors other than a genetically encoded autofluorescent protein, researchers must:
(2a) use NanoBRET®-branded energy acceptors (e.g., BRET-optimized HaloTag® ligands) for all determinations of energy transfer activity by this product and its derivatives; or
(2b) contact Promega to obtain a license for use of the product and its derivatives for energy transfer assays to energy acceptors not manufactured by Promega.

Researchers may transfer derivatives to others for research use provided that at the time of transfer a copy of this label license is given to the recipients and recipients agree to be bound by the terms of this label license. With respect to any uses outside this label license, including any diagnostic, therapeutic, prophylactic or commercial uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE PRODUCT. The terms of this agreement shall be governed under the laws of the State of Wisconsin, USA.

U.S. Pat. Nos. 8,557,970, 8,669,103, 9,777,311, 9,840,730, 9,951,373, 10,233,485, 10,633,690, 10,774,364, 10,844,422, 11,365,436, 11,661,623, 11,667,950; European Pat. Nos. 2456864, 2635595, 2990478, 3181687, 3409764; Japanese Pat. Nos. 6038649, 6155424, 6227615, 6374420, 6539689; and other patents and patents pending.

Specifications

You are viewing: N1321 Change Configuration

What's in the box?

Item Part # Size Concentration

pFN31K Nluc CMV-neo Flexi® Vector

N132A 1 × 20μg 0.1μg/μl

Certificate of Analysis

Search by lot number

Use Restrictions

For Research Use Only. Not for Use in Diagnostic Procedures.

Storage Conditions

BB

Patents and Disclaimers

BY USE OF THIS PRODUCT, RESEARCHER AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE. If researcher is not willing to accept the conditions of this limited use statement, and the product is unused, Promega will accept return of the unused product and provide researcher with a full refund.

Researchers may use this product for research use only; no transfer or commercial use of this product is allowed. Commercial use means any and all uses of this product or derivatives by a party in exchange for consideration, including, but not limited to (1) use in further product manufacture; (2) use in provision of services, information or data; and (3) resale of the product or its derivatives, whether or not such product or derivatives are resold for use in research. Researchers shall have no right to modify or otherwise create variations of the nucleotide sequence of the luciferase gene except that researcher may (1) create fused gene sequences provided that the coding sequence of the resulting luciferase gene has no more than four deoxynucleotides missing at the affected terminus compared to the intact luciferase gene sequence; and (2) insert and remove nucleic acid sequences in splicing research predicated on the inactivation or reconstitution of the luminescence of the encoded luciferase. No other use of this product or derivatives is authorized without the prior express written consent of Promega.

In addition, researchers must:
(1a) use Nano-Glo®-branded luminescent assay reagents (LARs) for all determinations of luminescence activity of this product and its derivatives; or
(1b) contact Promega to obtain a license for use of the product and its derivatives with LARs not manufactured by Promega.

For uses of Nano-Glo®-branded LARs intended for energy transfer (such as bioluminescence resonance energy transfer) to acceptors other than a genetically encoded autofluorescent protein, researchers must:
(2a) use NanoBRET®-branded energy acceptors (e.g., BRET-optimized HaloTag® ligands) for all determinations of energy transfer activity by this product and its derivatives; or
(2b) contact Promega to obtain a license for use of the product and its derivatives for energy transfer assays to energy acceptors not manufactured by Promega.

Researchers may transfer derivatives to others for research use provided that at the time of transfer a copy of this label license is given to the recipients and recipients agree to be bound by the terms of this label license. With respect to any uses outside this label license, including any diagnostic, therapeutic, prophylactic or commercial uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE PRODUCT. The terms of this agreement shall be governed under the laws of the State of Wisconsin, USA.

U.S. Pat. Nos. 8,293,503, 9,018,014 and 8,367,403, European Pat. No. 1685247 and other patents and patents pending.

U.S. Pat. Nos. 8,557,970, 8,669,103, 9,777,311, 9,840,730, 9,951,373, 10,233,485, 10,633,690, 10,774,364, 10,844,422, 11,365,436, 11,661,623, 11,667,950; European Pat. Nos. 2456864, 2635595, 2990478, 3181687, 3409764; Japanese Pat. Nos. 6038649, 6155424, 6227615, 6374420, 6539689; and other patents and patents pending.

Specifications

You are viewing: N1331 Change Configuration

What's in the box?

Item Part # Size Concentration

pFC32A Nluc CMV-Hygro Flexi® Vector

N133A 1 × 20μg 0.1μg/μl

Certificate of Analysis

Search by lot number

Use Restrictions

For Research Use Only. Not for Use in Diagnostic Procedures.

Storage Conditions

BB

Patents and Disclaimers

BY USE OF THIS PRODUCT, RESEARCHER AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE. If researcher is not willing to accept the conditions of this limited use statement, and the product is unused, Promega will accept return of the unused product and provide researcher with a full refund.

Researchers may use this product for research use only; no transfer or commercial use of this product is allowed. Commercial use means any and all uses of this product or derivatives by a party in exchange for consideration, including, but not limited to (1) use in further product manufacture; (2) use in provision of services, information or data; and (3) resale of the product or its derivatives, whether or not such product or derivatives are resold for use in research. Researchers shall have no right to modify or otherwise create variations of the nucleotide sequence of the luciferase gene except that researcher may (1) create fused gene sequences provided that the coding sequence of the resulting luciferase gene has no more than four deoxynucleotides missing at the affected terminus compared to the intact luciferase gene sequence; and (2) insert and remove nucleic acid sequences in splicing research predicated on the inactivation or reconstitution of the luminescence of the encoded luciferase. No other use of this product or derivatives is authorized without the prior express written consent of Promega.

In addition, researchers must:
(1a) use Nano-Glo®-branded luminescent assay reagents (LARs) for all determinations of luminescence activity of this product and its derivatives; or
(1b) contact Promega to obtain a license for use of the product and its derivatives with LARs not manufactured by Promega.

For uses of Nano-Glo®-branded LARs intended for energy transfer (such as bioluminescence resonance energy transfer) to acceptors other than a genetically encoded autofluorescent protein, researchers must:
(2a) use NanoBRET®-branded energy acceptors (e.g., BRET-optimized HaloTag® ligands) for all determinations of energy transfer activity by this product and its derivatives; or
(2b) contact Promega to obtain a license for use of the product and its derivatives for energy transfer assays to energy acceptors not manufactured by Promega.

Researchers may transfer derivatives to others for research use provided that at the time of transfer a copy of this label license is given to the recipients and recipients agree to be bound by the terms of this label license. With respect to any uses outside this label license, including any diagnostic, therapeutic, prophylactic or commercial uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE PRODUCT. The terms of this agreement shall be governed under the laws of the State of Wisconsin, USA.

U.S. Pat. Nos. 8,557,970, 8,669,103, 9,777,311, 9,840,730, 9,951,373, 10,233,485, 10,633,690, 10,774,364, 10,844,422, 11,365,436, 11,661,623, 11,667,950; European Pat. Nos. 2456864, 2635595, 2990478, 3181687, 3409764; Japanese Pat. Nos. 6038649, 6155424, 6227615, 6374420, 6539689; and other patents and patents pending.

Specifications

You are viewing: N1341 Change Configuration

What's in the box?

Item Part # Size Concentration

pFC32K Nluc CMV-neo Flexi® Vector

N134A 1 × 20μg 0.1μg/μl

Certificate of Analysis

Search by lot number

Use Restrictions

For Research Use Only. Not for Use in Diagnostic Procedures.

Storage Conditions

BB

Patents and Disclaimers

BY USE OF THIS PRODUCT, RESEARCHER AGREES TO BE BOUND BY THE TERMS OF THIS LIMITED USE LABEL LICENSE. If researcher is not willing to accept the conditions of this limited use statement, and the product is unused, Promega will accept return of the unused product and provide researcher with a full refund.

Researchers may use this product for research use only; no transfer or commercial use of this product is allowed. Commercial use means any and all uses of this product or derivatives by a party in exchange for consideration, including, but not limited to (1) use in further product manufacture; (2) use in provision of services, information or data; and (3) resale of the product or its derivatives, whether or not such product or derivatives are resold for use in research. Researchers shall have no right to modify or otherwise create variations of the nucleotide sequence of the luciferase gene except that researcher may (1) create fused gene sequences provided that the coding sequence of the resulting luciferase gene has no more than four deoxynucleotides missing at the affected terminus compared to the intact luciferase gene sequence; and (2) insert and remove nucleic acid sequences in splicing research predicated on the inactivation or reconstitution of the luminescence of the encoded luciferase. No other use of this product or derivatives is authorized without the prior express written consent of Promega.

In addition, researchers must:
(1a) use Nano-Glo®-branded luminescent assay reagents (LARs) for all determinations of luminescence activity of this product and its derivatives; or
(1b) contact Promega to obtain a license for use of the product and its derivatives with LARs not manufactured by Promega.

For uses of Nano-Glo®-branded LARs intended for energy transfer (such as bioluminescence resonance energy transfer) to acceptors other than a genetically encoded autofluorescent protein, researchers must:
(2a) use NanoBRET®-branded energy acceptors (e.g., BRET-optimized HaloTag® ligands) for all determinations of energy transfer activity by this product and its derivatives; or
(2b) contact Promega to obtain a license for use of the product and its derivatives for energy transfer assays to energy acceptors not manufactured by Promega.

Researchers may transfer derivatives to others for research use provided that at the time of transfer a copy of this label license is given to the recipients and recipients agree to be bound by the terms of this label license. With respect to any uses outside this label license, including any diagnostic, therapeutic, prophylactic or commercial uses, please contact Promega for supply and licensing information. PROMEGA MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WITH REGARD TO THE PRODUCT. The terms of this agreement shall be governed under the laws of the State of Wisconsin, USA.

U.S. Pat. Nos. 8,557,970, 8,669,103, 9,777,311, 9,840,730, 9,951,373, 10,233,485, 10,633,690, 10,774,364, 10,844,422, 11,365,436, 11,661,623, 11,667,950; European Pat. Nos. 2456864, 2635595, 2990478, 3181687, 3409764; Japanese Pat. Nos. 6038649, 6155424, 6227615, 6374420, 6539689; and other patents and patents pending.

U.S. Pat. Nos. 8,293,503, 9,018,014 and 8,367,403, European Pat. No. 1685247 and other patents and patents pending.

Let's find the product that meets your needs.

Talk to a Scientist

Paraj

Paraj

US